With some configuration option combinations, we get the following
warnings:

drivers/hwmon/lm90.c: In function 'lm90_detect':
drivers/hwmon/lm90.c:1114: warning: 'chip_id' may be used uninitialized
in this function
drivers/hwmon/lm90.c:1114: warning: 'reg_config1' may be used
uninitialized in this function
drivers/hwmon/lm90.c:1114: warning: 'reg_convrate' may be used
uninitialized in this function
drivers/hwmon/lm90.c:1187: warning: 'reg_emerg2' may be used
uninitialized in this function
drivers/hwmon/lm90.c:1187: warning: 'reg_status2' may be used
uninitialized in this function

We can solve these easily by reading the register values first and
checking for errors later. These errors should be very rare, even in
the case of failed detection, so this change has no impact on
performance. And this makes checkpatch.pl happier.

Reported-by: Guenter Roeck <guenter.roeck@ericsson.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Acked-by: Guenter Roeck <guenter.roeck@ericsson.com>
This commit is contained in:
Jean Delvare 2011-11-04 12:00:46 +01:00 коммит произвёл Jean Delvare
Родитель da8ebe4e09
Коммит 8dc089d68b
1 изменённых файлов: 16 добавлений и 15 удалений

Просмотреть файл

@ -1117,14 +1117,12 @@ static int lm90_detect(struct i2c_client *new_client,
return -ENODEV;
/* detection and identification */
if ((man_id = i2c_smbus_read_byte_data(new_client,
LM90_REG_R_MAN_ID)) < 0
|| (chip_id = i2c_smbus_read_byte_data(new_client,
LM90_REG_R_CHIP_ID)) < 0
|| (reg_config1 = i2c_smbus_read_byte_data(new_client,
LM90_REG_R_CONFIG1)) < 0
|| (reg_convrate = i2c_smbus_read_byte_data(new_client,
LM90_REG_R_CONVRATE)) < 0)
man_id = i2c_smbus_read_byte_data(new_client, LM90_REG_R_MAN_ID);
chip_id = i2c_smbus_read_byte_data(new_client, LM90_REG_R_CHIP_ID);
reg_config1 = i2c_smbus_read_byte_data(new_client, LM90_REG_R_CONFIG1);
reg_convrate = i2c_smbus_read_byte_data(new_client,
LM90_REG_R_CONVRATE);
if (man_id < 0 || chip_id < 0 || reg_config1 < 0 || reg_convrate < 0)
return -ENODEV;
if (man_id == 0x01 || man_id == 0x5C || man_id == 0x41) {
@ -1192,13 +1190,16 @@ static int lm90_detect(struct i2c_client *new_client,
* exists, both readings will reflect the same value. Otherwise,
* the readings will be different.
*/
if ((reg_emerg = i2c_smbus_read_byte_data(new_client,
MAX6659_REG_R_REMOTE_EMERG)) < 0
|| i2c_smbus_read_byte_data(new_client, LM90_REG_R_MAN_ID) < 0
|| (reg_emerg2 = i2c_smbus_read_byte_data(new_client,
MAX6659_REG_R_REMOTE_EMERG)) < 0
|| (reg_status2 = i2c_smbus_read_byte_data(new_client,
MAX6696_REG_R_STATUS2)) < 0)
reg_emerg = i2c_smbus_read_byte_data(new_client,
MAX6659_REG_R_REMOTE_EMERG);
man_id = i2c_smbus_read_byte_data(new_client,
LM90_REG_R_MAN_ID);
reg_emerg2 = i2c_smbus_read_byte_data(new_client,
MAX6659_REG_R_REMOTE_EMERG);
reg_status2 = i2c_smbus_read_byte_data(new_client,
MAX6696_REG_R_STATUS2);
if (reg_emerg < 0 || man_id < 0 || reg_emerg2 < 0
|| reg_status2 < 0)
return -ENODEV;
/*