Thermal: Add get trend, get instance API's to thermal_sys

This patch adds the following API's to thermal_sys.c, that
can be used by other Thermal drivers.
 * get_tz_trend: obtain the trend of the given thermal zone
 * get_thermal_instance: obtain the instance corresponding
   to the given tz, cdev and the trip point.

Signed-off-by: Durgadoss R <durgadoss.r@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This commit is contained in:
Durgadoss R 2012-09-18 11:04:54 +05:30 коммит произвёл Zhang Rui
Родитель 71350db43b
Коммит 9b4298a088
2 изменённых файлов: 44 добавлений и 0 удалений

Просмотреть файл

@ -82,6 +82,46 @@ static void release_idr(struct idr *idr, struct mutex *lock, int id)
mutex_unlock(lock);
}
int get_tz_trend(struct thermal_zone_device *tz, int trip)
{
enum thermal_trend trend;
if (!tz->ops->get_trend || tz->ops->get_trend(tz, trip, &trend)) {
if (tz->temperature > tz->last_temperature)
trend = THERMAL_TREND_RAISING;
else if (tz->temperature < tz->last_temperature)
trend = THERMAL_TREND_DROPPING;
else
trend = THERMAL_TREND_STABLE;
}
return trend;
}
EXPORT_SYMBOL(get_tz_trend);
struct thermal_instance *get_thermal_instance(struct thermal_zone_device *tz,
struct thermal_cooling_device *cdev, int trip)
{
struct thermal_instance *pos = NULL;
struct thermal_instance *target_instance = NULL;
mutex_lock(&tz->lock);
mutex_lock(&cdev->lock);
list_for_each_entry(pos, &tz->thermal_instances, tz_node) {
if (pos->tz == tz && pos->trip == trip && pos->cdev == cdev) {
target_instance = pos;
break;
}
}
mutex_unlock(&cdev->lock);
mutex_unlock(&tz->lock);
return target_instance;
}
EXPORT_SYMBOL(get_thermal_instance);
/* sys I/F for thermal zone */
#define to_thermal_zone(_dev) \

Просмотреть файл

@ -185,6 +185,10 @@ struct thermal_cooling_device *thermal_cooling_device_register(char *, void *,
const struct thermal_cooling_device_ops *);
void thermal_cooling_device_unregister(struct thermal_cooling_device *);
int get_tz_trend(struct thermal_zone_device *, int);
struct thermal_instance *get_thermal_instance(struct thermal_zone_device *,
struct thermal_cooling_device *, int);
#ifdef CONFIG_NET
extern int thermal_generate_netlink_event(u32 orig, enum events event);
#else