serial: stm32: add FIFO flush when port is closed

Transmission complete error is sent when ISR_TC is not set. If port closure
is requested despite data in TDR / TX FIFO has not been sent (because of
flow control), ISR_TC is not set and error message is sent on port closure
but also when a new port is opened.

Flush the data when port is closed, so the error isn't printed twice upon
next port opening.

Fixes: 64c32eab66 ("serial: stm32: Add support of TC bit status check")
Signed-off-by: Erwan Le Ray <erwan.leray@foss.st.com>
Link: https://lore.kernel.org/r/20210304162308.8984-12-erwan.leray@foss.st.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Erwan Le Ray 2021-03-04 17:23:06 +01:00 коммит произвёл Greg Kroah-Hartman
Родитель 315e2d8a12
Коммит 9f77d19207
1 изменённых файлов: 5 добавлений и 0 удалений

Просмотреть файл

@ -691,6 +691,11 @@ static void stm32_usart_shutdown(struct uart_port *port)
if (ret)
dev_err(port->dev, "Transmission is not complete\n");
/* flush RX & TX FIFO */
if (ofs->rqr != UNDEF_REG)
writel_relaxed(USART_RQR_TXFRQ | USART_RQR_RXFRQ,
port->membase + ofs->rqr);
stm32_usart_clr_bits(port, ofs->cr1, val);
free_irq(port->irq, port);