IB/mlx4: Unregister IB device prior to CLOSE PORT command

According to the ConnectX programmer's reference manual, all
operations should be stopped, all QPs should be torn down and all WQEs
flushed before the CLOSE_PORT command is invoked.  In some cases
reversing the order of operations (as implemented now) could cause
a loss of completions.

Signed-off-by: Yevgeny Petrilin <yevgenyp@mellanox.co.il>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
This commit is contained in:
Yevgeny Petrilin 2009-03-18 19:49:54 -07:00 коммит произвёл Roland Dreier
Родитель 27bf91d6a0
Коммит a6a47771b1
1 изменённых файлов: 3 добавлений и 2 удалений

Просмотреть файл

@ -699,11 +699,12 @@ static void mlx4_ib_remove(struct mlx4_dev *dev, void *ibdev_ptr)
struct mlx4_ib_dev *ibdev = ibdev_ptr;
int p;
mlx4_ib_mad_cleanup(ibdev);
ib_unregister_device(&ibdev->ib_dev);
for (p = 1; p <= ibdev->num_ports; ++p)
mlx4_CLOSE_PORT(dev, p);
mlx4_ib_mad_cleanup(ibdev);
ib_unregister_device(&ibdev->ib_dev);
iounmap(ibdev->uar_map);
mlx4_uar_free(dev, &ibdev->priv_uar);
mlx4_pd_free(dev, ibdev->priv_pdn);