HID: sony: Perform a boundry check on the sixaxis battery level index.

Make sure that an out-of-bounds read doesn't occur in the Sixaxis battery level
lookup table in the event that the controller sends an invalid battery status
value in the report.

Signed-off-by: Frank Praznik <frank.praznik@oh.rr.com>
Reviewed-by: David Herrmann <dh.herrmann@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
Frank Praznik 2014-02-20 11:36:02 -05:00 коммит произвёл Jiri Kosina
Родитель c8de9dbb35
Коммит ac3c9a9409
1 изменённых файлов: 2 добавлений и 1 удалений

Просмотреть файл

@ -854,7 +854,8 @@ static void sixaxis_parse_report(struct sony_sc *sc, __u8 *rd, int size)
battery_capacity = 100;
battery_charging = !(rd[30] & 0x01);
} else {
battery_capacity = sixaxis_battery_capacity[rd[30]];
__u8 index = rd[30] <= 5 ? rd[30] : 5;
battery_capacity = sixaxis_battery_capacity[index];
battery_charging = 0;
}
cable_state = !((rd[31] >> 4) & 0x01);