doc: Make sysfs-bus-iio doc more exact
A few IIC channel descriptions explained used units as: data is in foo "that can be processed into an" [unit] value. The "can be processed into" is quite broad statement as it does not really explain what this processing means. This makes units pretty much useless. After discussion with Jonathan, it seems the units for these channels should also be well-defined as for all other channels. The processing means the standard scale and offset application that is used throughout the IIO. Let's make it more obvious by stating that the units are [unit] after scale ane offset are applied. Signed-off-by: Matti Vaittinen <mazziesaccount@gmail.com> Link: https://lore.kernel.org/r/41eafb0caa510cddf650cf5ff940639a184f3005.1677331779.git.mazziesaccount@gmail.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Родитель
f1caa90085
Коммит
b27f0b40e4
|
@ -1807,8 +1807,8 @@ What: /sys/bus/iio/devices/iio:deviceX/out_resistanceX_raw
|
||||||
KernelVersion: 4.3
|
KernelVersion: 4.3
|
||||||
Contact: linux-iio@vger.kernel.org
|
Contact: linux-iio@vger.kernel.org
|
||||||
Description:
|
Description:
|
||||||
Raw (unscaled no offset etc.) resistance reading that can be processed
|
Raw (unscaled no offset etc.) resistance reading.
|
||||||
into an ohm value.
|
Units after application of scale and offset are ohms.
|
||||||
|
|
||||||
What: /sys/bus/iio/devices/iio:deviceX/heater_enable
|
What: /sys/bus/iio/devices/iio:deviceX/heater_enable
|
||||||
KernelVersion: 4.1.0
|
KernelVersion: 4.1.0
|
||||||
|
@ -1894,8 +1894,9 @@ What: /sys/bus/iio/devices/iio:deviceX/in_electricalconductivity_raw
|
||||||
KernelVersion: 4.8
|
KernelVersion: 4.8
|
||||||
Contact: linux-iio@vger.kernel.org
|
Contact: linux-iio@vger.kernel.org
|
||||||
Description:
|
Description:
|
||||||
Raw (unscaled no offset etc.) electric conductivity reading that
|
Raw (unscaled no offset etc.) electric conductivity reading.
|
||||||
can be processed to siemens per meter.
|
Units after application of scale and offset are siemens per
|
||||||
|
meter.
|
||||||
|
|
||||||
What: /sys/bus/iio/devices/iio:deviceX/in_countY_raw
|
What: /sys/bus/iio/devices/iio:deviceX/in_countY_raw
|
||||||
KernelVersion: 4.10
|
KernelVersion: 4.10
|
||||||
|
@ -1951,8 +1952,8 @@ What: /sys/bus/iio/devices/iio:deviceX/in_phaseY_raw
|
||||||
KernelVersion: 4.18
|
KernelVersion: 4.18
|
||||||
Contact: linux-iio@vger.kernel.org
|
Contact: linux-iio@vger.kernel.org
|
||||||
Description:
|
Description:
|
||||||
Raw (unscaled) phase difference reading from channel Y
|
Raw (unscaled) phase difference reading from channel Y.
|
||||||
that can be processed to radians.
|
Units after application of scale and offset are radians.
|
||||||
|
|
||||||
What: /sys/bus/iio/devices/iio:deviceX/in_massconcentration_pm1_input
|
What: /sys/bus/iio/devices/iio:deviceX/in_massconcentration_pm1_input
|
||||||
What: /sys/bus/iio/devices/iio:deviceX/in_massconcentrationY_pm1_input
|
What: /sys/bus/iio/devices/iio:deviceX/in_massconcentrationY_pm1_input
|
||||||
|
|
Загрузка…
Ссылка в новой задаче