md/raid1: add error handling of read error from FailFast device
Current handle_read_error() function calls fix_read_error() only if md device is RW and rdev does not include FailFast flag. It does not handle a read error from a RW device including FailFast flag. I am not sure it is intended. But I found that write IO error sets rdev faulty. The md module should handle the read IO error and write IO error equally. So I think read IO error should set rdev faulty. Signed-off-by: Gioh Kim <gi-oh.kim@profitbricks.com> Reviewed-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Shaohua Li <shli@fb.com>
This commit is contained in:
Родитель
c42a0e2675
Коммит
b33d10624f
|
@ -2472,6 +2472,8 @@ static void handle_read_error(struct r1conf *conf, struct r1bio *r1_bio)
|
|||
fix_read_error(conf, r1_bio->read_disk,
|
||||
r1_bio->sector, r1_bio->sectors);
|
||||
unfreeze_array(conf);
|
||||
} else if (mddev->ro == 0 && test_bit(FailFast, &rdev->flags)) {
|
||||
md_error(mddev, rdev);
|
||||
} else {
|
||||
r1_bio->bios[r1_bio->read_disk] = IO_BLOCKED;
|
||||
}
|
||||
|
|
Загрузка…