drivers: staging: cedrus: find ctx before dereferencing it ctx

Currently if count is an invalid value the v4l2_info message will
dereference a null ctx pointer to get the dev information. Fix
this by finding ctx first and then checking for an invalid count,
this way ctxt will be non-null hence avoiding the null pointer
dereference.

Detected by CoverityScan, CID#1475337 ("Explicit null dereferenced")

Fixes: 50e761516f ("media: platform: Add Cedrus VPU decoder driver")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Acked-by: Maxime Ripard <maxime.ripard@bootlin.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Colin Ian King 2018-11-02 19:01:26 +00:00 коммит произвёл Greg Kroah-Hartman
Родитель c3e43d8b95
Коммит b7c56d7bfe
1 изменённых файлов: 11 добавлений и 11 удалений

Просмотреть файл

@ -108,17 +108,6 @@ static int cedrus_request_validate(struct media_request *req)
unsigned int count;
unsigned int i;
count = vb2_request_buffer_cnt(req);
if (!count) {
v4l2_info(&ctx->dev->v4l2_dev,
"No buffer was provided with the request\n");
return -ENOENT;
} else if (count > 1) {
v4l2_info(&ctx->dev->v4l2_dev,
"More than one buffer was provided with the request\n");
return -EINVAL;
}
list_for_each_entry(obj, &req->objects, list) {
struct vb2_buffer *vb;
@ -133,6 +122,17 @@ static int cedrus_request_validate(struct media_request *req)
if (!ctx)
return -ENOENT;
count = vb2_request_buffer_cnt(req);
if (!count) {
v4l2_info(&ctx->dev->v4l2_dev,
"No buffer was provided with the request\n");
return -ENOENT;
} else if (count > 1) {
v4l2_info(&ctx->dev->v4l2_dev,
"More than one buffer was provided with the request\n");
return -EINVAL;
}
parent_hdl = &ctx->hdl;
hdl = v4l2_ctrl_request_hdl_find(req, parent_hdl);