ARM: bcm2835: fix clock DT node names
DT nodes should be named according to the type of object that they represent rather than the identity. DT nodes that contain a reg property should include a unit address in their name. Fix these issues. Add clock-output-names properties to the nodes so that the clocks get named something meaningful. This works around the fact that the fixed clock driver names clocks after the short node name, i.e. not including the unit address. Signed-off-by: Stephen Warren <swarren@wwwdotorg.org>
This commit is contained in:
Родитель
25b2f1bd0b
Коммит
b7c6c17606
|
@ -155,24 +155,27 @@
|
|||
#address-cells = <1>;
|
||||
#size-cells = <0>;
|
||||
|
||||
clk_mmc: mmc {
|
||||
clk_mmc: clock@0 {
|
||||
compatible = "fixed-clock";
|
||||
reg = <0>;
|
||||
#clock-cells = <0>;
|
||||
clock-output-names = "mmc";
|
||||
clock-frequency = <100000000>;
|
||||
};
|
||||
|
||||
clk_i2c: i2c {
|
||||
clk_i2c: clock@1 {
|
||||
compatible = "fixed-clock";
|
||||
reg = <1>;
|
||||
#clock-cells = <0>;
|
||||
clock-output-names = "i2c";
|
||||
clock-frequency = <250000000>;
|
||||
};
|
||||
|
||||
clk_spi: spi {
|
||||
clk_spi: clock@2 {
|
||||
compatible = "fixed-clock";
|
||||
reg = <2>;
|
||||
#clock-cells = <0>;
|
||||
clock-output-names = "spi";
|
||||
clock-frequency = <250000000>;
|
||||
};
|
||||
};
|
||||
|
|
Загрузка…
Ссылка в новой задаче