thermal: devfreq_cooling: change tracing function and arguments
Prepare for deleting the static and dynamic power calculation and clean the trace function. These two fields are going to be removed in the next changes. Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com> Reviewed-by: Steven Rostedt (VMware) <rostedt@goodmis.org> # for tracing code Signed-off-by: Lukasz Luba <lukasz.luba@arm.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20201210143014.24685-2-lukasz.luba@arm.com
This commit is contained in:
Родитель
ac35e6cb9e
Коммит
b8643a5299
|
@ -277,8 +277,7 @@ static int devfreq_cooling_get_requested_power(struct thermal_cooling_device *cd
|
|||
*power = dyn_power + static_power;
|
||||
}
|
||||
|
||||
trace_thermal_power_devfreq_get_power(cdev, status, freq, dyn_power,
|
||||
static_power, *power);
|
||||
trace_thermal_power_devfreq_get_power(cdev, status, freq, *power);
|
||||
|
||||
return 0;
|
||||
fail:
|
||||
|
|
|
@ -153,31 +153,30 @@ TRACE_EVENT(thermal_power_cpu_limit,
|
|||
TRACE_EVENT(thermal_power_devfreq_get_power,
|
||||
TP_PROTO(struct thermal_cooling_device *cdev,
|
||||
struct devfreq_dev_status *status, unsigned long freq,
|
||||
u32 dynamic_power, u32 static_power, u32 power),
|
||||
u32 power),
|
||||
|
||||
TP_ARGS(cdev, status, freq, dynamic_power, static_power, power),
|
||||
TP_ARGS(cdev, status, freq, power),
|
||||
|
||||
TP_STRUCT__entry(
|
||||
__string(type, cdev->type )
|
||||
__field(unsigned long, freq )
|
||||
__field(u32, load )
|
||||
__field(u32, dynamic_power )
|
||||
__field(u32, static_power )
|
||||
__field(u32, busy_time)
|
||||
__field(u32, total_time)
|
||||
__field(u32, power)
|
||||
),
|
||||
|
||||
TP_fast_assign(
|
||||
__assign_str(type, cdev->type);
|
||||
__entry->freq = freq;
|
||||
__entry->load = (100 * status->busy_time) / status->total_time;
|
||||
__entry->dynamic_power = dynamic_power;
|
||||
__entry->static_power = static_power;
|
||||
__entry->busy_time = status->busy_time;
|
||||
__entry->total_time = status->total_time;
|
||||
__entry->power = power;
|
||||
),
|
||||
|
||||
TP_printk("type=%s freq=%lu load=%u dynamic_power=%u static_power=%u power=%u",
|
||||
TP_printk("type=%s freq=%lu load=%u power=%u",
|
||||
__get_str(type), __entry->freq,
|
||||
__entry->load, __entry->dynamic_power, __entry->static_power,
|
||||
__entry->total_time == 0 ? 0 :
|
||||
(100 * __entry->busy_time) / __entry->total_time,
|
||||
__entry->power)
|
||||
);
|
||||
|
||||
|
|
Загрузка…
Ссылка в новой задаче