sound: seq_midi: do not send MIDI reset when closing

Sending a MIDI reset message when closing a port is wrong because we
only want to shut the device up, not to reset all settings.
Furthermore, many devices ignore this message.

Fortunately, the RawMIDI layer already shuts the device up, so we can
ignore this matter here.

Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
Clemens Ladisch 2009-07-13 13:50:17 +02:00 коммит произвёл Takashi Iwai
Родитель f907ed94f9
Коммит b86c87288c
1 изменённых файлов: 0 добавлений и 3 удалений

Просмотреть файл

@ -249,12 +249,9 @@ static int midisynth_use(void *private_data, struct snd_seq_port_subscribe *info
static int midisynth_unuse(void *private_data, struct snd_seq_port_subscribe *info)
{
struct seq_midisynth *msynth = private_data;
unsigned char buf = 0xff; /* MIDI reset */
if (snd_BUG_ON(!msynth->output_rfile.output))
return -EINVAL;
/* sending single MIDI reset message to shut the device up */
snd_rawmidi_kernel_write(msynth->output_rfile.output, &buf, 1);
snd_rawmidi_drain_output(msynth->output_rfile.output);
return snd_rawmidi_kernel_release(&msynth->output_rfile);
}