iio: mxs-lradc: Fix temperature offset
0° Kelvin is actually −273.15°C, not -272.15°C. Fix the temperature offset. Also improve the comment explaining the calculation. Reported-by: Janusz Użycki <j.uzycki@elpromaelectronics.com> Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com> Acked-by: Stefan Wahren <stefan.wahren@i2se.com> Acked-by: Marek Vasut <marex@denx.de> Cc: <stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
Родитель
eda7d0f38a
Коммит
b94e22805a
|
@ -915,11 +915,12 @@ static int mxs_lradc_read_raw(struct iio_dev *iio_dev,
|
|||
case IIO_CHAN_INFO_OFFSET:
|
||||
if (chan->type == IIO_TEMP) {
|
||||
/* The calculated value from the ADC is in Kelvin, we
|
||||
* want Celsius for hwmon so the offset is
|
||||
* -272.15 * scale
|
||||
* want Celsius for hwmon so the offset is -273.15
|
||||
* The offset is applied before scaling so it is
|
||||
* actually -213.15 * 4 / 1.012 = -1079.644268
|
||||
*/
|
||||
*val = -1075;
|
||||
*val2 = 691699;
|
||||
*val = -1079;
|
||||
*val2 = 644268;
|
||||
|
||||
return IIO_VAL_INT_PLUS_MICRO;
|
||||
}
|
||||
|
|
Загрузка…