[media] media: adv7604: ability to read default input port from DT

Adds support to the adv7604 driver for specifying the default input
port in the Device tree. If no value is provided, the driver will be
unable to select an input without help from userspace.

Tested-by: William Towle <william.towle@codethink.co.uk>
Signed-off-by: Ian Molton <ian.molton@codethink.co.uk>
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
This commit is contained in:
Ian Molton 2015-06-03 10:59:53 -03:00 коммит произвёл Mauro Carvalho Chehab
Родитель 6a219f15a8
Коммит bf9c82278c
2 изменённых файлов: 10 добавлений и 1 удалений

Просмотреть файл

@ -47,6 +47,7 @@ Optional Endpoint Properties:
If none of hsync-active, vsync-active and pclk-sample is specified the
endpoint will use embedded BT.656 synchronization.
- default-input: Select which input is selected after reset.
Example:
@ -60,6 +61,8 @@ Example:
#address-cells = <1>;
#size-cells = <0>;
default-input = <0>;
port@0 {
reg = <0>;
};

Просмотреть файл

@ -2772,6 +2772,7 @@ static int adv76xx_parse_dt(struct adv76xx_state *state)
struct device_node *endpoint;
struct device_node *np;
unsigned int flags;
u32 v;
np = state->i2c_clients[ADV76XX_PAGE_IO]->dev.of_node;
@ -2781,6 +2782,12 @@ static int adv76xx_parse_dt(struct adv76xx_state *state)
return -EINVAL;
v4l2_of_parse_endpoint(endpoint, &bus_cfg);
if (!of_property_read_u32(endpoint, "default-input", &v))
state->pdata.default_input = v;
else
state->pdata.default_input = -1;
of_node_put(endpoint);
flags = bus_cfg.bus.parallel.flags;
@ -2819,7 +2826,6 @@ static int adv76xx_parse_dt(struct adv76xx_state *state)
/* Hardcode the remaining platform data fields. */
state->pdata.disable_pwrdnb = 0;
state->pdata.disable_cable_det_rst = 0;
state->pdata.default_input = -1;
state->pdata.blank_data = 1;
state->pdata.alt_data_sat = 1;
state->pdata.op_format_mode_sel = ADV7604_OP_FORMAT_MODE0;