media: ov2680: fix null dereference at power on
Swapping the order between v4l2 subdevice registration and checking chip id inb7a417628a
("media: ov2680: don't register the v4l2 subdevice before checking chip ID") makes the mode restore to use the sensor controls before they are set, so move the mode restore call to s_power after the handler setup for controls is done. This remove also the need for the error code path in power on function. Fixes:b7a417628a
("media: ov2680: don't register the v4l2 subdevice before checking chip ID") Signed-off-by: Rui Miguel Silva <rui.silva@linaro.org> Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com> Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
This commit is contained in:
Родитель
5f229dcabc
Коммит
c45fbdf24c
|
@ -568,10 +568,6 @@ static int ov2680_power_on(struct ov2680_dev *sensor)
|
|||
if (ret < 0)
|
||||
return ret;
|
||||
|
||||
ret = ov2680_mode_restore(sensor);
|
||||
if (ret < 0)
|
||||
goto disable;
|
||||
|
||||
sensor->is_enabled = true;
|
||||
|
||||
/* Set clock lane into LP-11 state */
|
||||
|
@ -580,12 +576,6 @@ static int ov2680_power_on(struct ov2680_dev *sensor)
|
|||
ov2680_stream_disable(sensor);
|
||||
|
||||
return 0;
|
||||
|
||||
disable:
|
||||
dev_err(dev, "failed to enable sensor: %d\n", ret);
|
||||
ov2680_power_off(sensor);
|
||||
|
||||
return ret;
|
||||
}
|
||||
|
||||
static int ov2680_s_power(struct v4l2_subdev *sd, int on)
|
||||
|
@ -606,6 +596,8 @@ static int ov2680_s_power(struct v4l2_subdev *sd, int on)
|
|||
ret = v4l2_ctrl_handler_setup(&sensor->ctrls.handler);
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
|
||||
ret = ov2680_mode_restore(sensor);
|
||||
}
|
||||
|
||||
return ret;
|
||||
|
|
Загрузка…