MIPS: lantiq: add reset-controller api support
Add a reset-controller binding for the reset registers found on the lantiq SoC. Signed-off-by: John Crispin <blogic@openwrt.org> Patchwork: http://patchwork.linux-mips.org/patch/8043/ Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
This commit is contained in:
Родитель
05637f10e7
Коммит
c530781c93
|
@ -296,6 +296,8 @@ config LANTIQ
|
|||
select USE_OF
|
||||
select PINCTRL
|
||||
select PINCTRL_LANTIQ
|
||||
select ARCH_HAS_RESET_CONTROLLER
|
||||
select RESET_CONTROLLER
|
||||
|
||||
config LASAT
|
||||
bool "LASAT Networks platforms"
|
||||
|
|
|
@ -14,6 +14,7 @@
|
|||
#include <linux/delay.h>
|
||||
#include <linux/of_address.h>
|
||||
#include <linux/of_platform.h>
|
||||
#include <linux/reset-controller.h>
|
||||
|
||||
#include <asm/reboot.h>
|
||||
|
||||
|
@ -113,6 +114,66 @@ void ltq_reset_once(unsigned int module, ulong u)
|
|||
ltq_rcu_w32(ltq_rcu_r32(RCU_RST_REQ) & ~module, RCU_RST_REQ);
|
||||
}
|
||||
|
||||
static int ltq_assert_device(struct reset_controller_dev *rcdev,
|
||||
unsigned long id)
|
||||
{
|
||||
u32 val;
|
||||
|
||||
if (id < 8)
|
||||
return -1;
|
||||
|
||||
val = ltq_rcu_r32(RCU_RST_REQ);
|
||||
val |= BIT(id);
|
||||
ltq_rcu_w32(val, RCU_RST_REQ);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int ltq_deassert_device(struct reset_controller_dev *rcdev,
|
||||
unsigned long id)
|
||||
{
|
||||
u32 val;
|
||||
|
||||
if (id < 8)
|
||||
return -1;
|
||||
|
||||
val = ltq_rcu_r32(RCU_RST_REQ);
|
||||
val &= ~BIT(id);
|
||||
ltq_rcu_w32(val, RCU_RST_REQ);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int ltq_reset_device(struct reset_controller_dev *rcdev,
|
||||
unsigned long id)
|
||||
{
|
||||
ltq_assert_device(rcdev, id);
|
||||
return ltq_deassert_device(rcdev, id);
|
||||
}
|
||||
|
||||
static struct reset_control_ops reset_ops = {
|
||||
.reset = ltq_reset_device,
|
||||
.assert = ltq_assert_device,
|
||||
.deassert = ltq_deassert_device,
|
||||
};
|
||||
|
||||
static struct reset_controller_dev reset_dev = {
|
||||
.ops = &reset_ops,
|
||||
.owner = THIS_MODULE,
|
||||
.nr_resets = 32,
|
||||
.of_reset_n_cells = 1,
|
||||
};
|
||||
|
||||
void ltq_rst_init(void)
|
||||
{
|
||||
reset_dev.of_node = of_find_compatible_node(NULL, NULL,
|
||||
"lantiq,xway-reset");
|
||||
if (!reset_dev.of_node)
|
||||
pr_err("Failed to find reset controller node");
|
||||
else
|
||||
reset_controller_register(&reset_dev);
|
||||
}
|
||||
|
||||
static void ltq_machine_restart(char *command)
|
||||
{
|
||||
local_irq_disable();
|
||||
|
|
Загрузка…
Ссылка в новой задаче