microblaze: Decrease time shifting values
Lower shifting values ensure that shifted 32bit counter value doesn't exceed 64bit cycle variable too fast. Signed-off-by: Michal Simek <monstr@monstr.eu>
This commit is contained in:
Родитель
615748aefa
Коммит
c8f77436d1
|
@ -28,6 +28,7 @@
|
|||
#include <asm/prom.h>
|
||||
#include <asm/irq.h>
|
||||
#include <asm/system.h>
|
||||
#include <linux/cnt32_to_63.h>
|
||||
|
||||
#ifdef CONFIG_SELFMOD_TIMER
|
||||
#include <asm/selfmod.h>
|
||||
|
@ -135,7 +136,7 @@ static void microblaze_timer_set_mode(enum clock_event_mode mode,
|
|||
static struct clock_event_device clockevent_microblaze_timer = {
|
||||
.name = "microblaze_clockevent",
|
||||
.features = CLOCK_EVT_FEAT_ONESHOT | CLOCK_EVT_FEAT_PERIODIC,
|
||||
.shift = 24,
|
||||
.shift = 8,
|
||||
.rating = 300,
|
||||
.set_next_event = microblaze_timer_set_next_event,
|
||||
.set_mode = microblaze_timer_set_mode,
|
||||
|
@ -195,7 +196,7 @@ static cycle_t microblaze_cc_read(const struct cyclecounter *cc)
|
|||
static struct cyclecounter microblaze_cc = {
|
||||
.read = microblaze_cc_read,
|
||||
.mask = CLOCKSOURCE_MASK(32),
|
||||
.shift = 24,
|
||||
.shift = 8,
|
||||
};
|
||||
|
||||
int __init init_microblaze_timecounter(void)
|
||||
|
@ -213,7 +214,7 @@ static struct clocksource clocksource_microblaze = {
|
|||
.rating = 300,
|
||||
.read = microblaze_read,
|
||||
.mask = CLOCKSOURCE_MASK(32),
|
||||
.shift = 24, /* I can shift it */
|
||||
.shift = 8, /* I can shift it */
|
||||
.flags = CLOCK_SOURCE_IS_CONTINUOUS,
|
||||
};
|
||||
|
||||
|
@ -302,7 +303,7 @@ unsigned long long notrace sched_clock(void)
|
|||
{
|
||||
if (timer_initialized) {
|
||||
struct clocksource *cs = &clocksource_microblaze;
|
||||
cycle_t cyc = cs->read(NULL);
|
||||
cycle_t cyc = cnt32_to_63(cs->read(NULL));
|
||||
return clocksource_cyc2ns(cyc, cs->mult, cs->shift);
|
||||
}
|
||||
return 0;
|
||||
|
|
Загрузка…
Ссылка в новой задаче