cpufreq: vexpress-spc: Switch cpumask from topology core to OPP sharing

Since commit ca74b316df ("arm: Use common cpu_topology structure and
functions.") the core cpumask has to be modified during cpu hotplug
operations. So using them to set up cpufreq policy cpumask may be
incorrect as it may contain only cpus that are online at that instance.

Instead, we can use the cpumask setup by OPP library that contains all
the cpus sharing OPP table using dev_pm_opp_get_sharing_cpus.

Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Tested-by: Dietmar Eggemann <dietmar.eggemann@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
This commit is contained in:
Sudeep Holla 2019-11-27 16:04:26 +00:00
Родитель 2a76352ad2
Коммит c9385887cb
1 изменённых файлов: 1 добавлений и 1 удалений

Просмотреть файл

@ -434,7 +434,7 @@ static int ve_spc_cpufreq_init(struct cpufreq_policy *policy)
if (cur_cluster < MAX_CLUSTERS) {
int cpu;
cpumask_copy(policy->cpus, topology_core_cpumask(policy->cpu));
dev_pm_opp_get_sharing_cpus(cpu_dev, policy->cpus);
for_each_cpu(cpu, policy->cpus)
per_cpu(physical_cluster, cpu) = cur_cluster;