phy: ti-pipe3: use ti_pipe3_power_off to power off the PHY during probe

No functional change. Previously omap_control_phy_power() was used to power
off the PHY during probe. But once PIPE3 driver is adapted to use syscon,
omap_control_phy_power() cannot be used. Hence used ti_pipe3_power_off
to power off the PHY.

Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Acked-by: Roger Quadros <rogerq@ti.com>
This commit is contained in:
Kishon Vijay Abraham I 2015-12-21 14:24:09 +05:30
Родитель 1fe521225a
Коммит cc34ace73d
1 изменённых файлов: 3 добавлений и 2 удалений

Просмотреть файл

@ -475,8 +475,6 @@ static int ti_pipe3_probe(struct platform_device *pdev)
if (ret)
return ret;
omap_control_phy_power(phy->control_dev, 0);
platform_set_drvdata(pdev, phy);
pm_runtime_enable(dev);
@ -495,6 +493,9 @@ static int ti_pipe3_probe(struct platform_device *pdev)
return PTR_ERR(generic_phy);
phy_set_drvdata(generic_phy, phy);
ti_pipe3_power_off(generic_phy);
phy_provider = devm_of_phy_provider_register(dev, of_phy_simple_xlate);
if (IS_ERR(phy_provider))
return PTR_ERR(phy_provider);