[PATCH] ipmi: fix panic generator ID

The IPMI specifcation says the generator ID is 0x20, but that is for bits
7-1.  Bit 0 is set to specify it is a software event.  The correct value is
0x41.  Without this fix, panic events written into the System Event Log
appear to come from an "unknown" generator, rather than from the kernel.

Signed-off-by: Jordan Hargrave <Jordan_Hargrave@dell.com>
Signed-off-by: Matt Domsch <Matt_Domsch@dell.com>
Acked-by: Corey Minyard <minyard@acm.org>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
This commit is contained in:
Matt Domsch 2005-12-12 00:37:32 -08:00 коммит произвёл Linus Torvalds
Родитель dd81540810
Коммит cda315aba3
1 изменённых файлов: 1 добавлений и 1 удалений

Просмотреть файл

@ -2986,7 +2986,7 @@ static void send_panic_events(char *str)
msg.cmd = 2; /* Platform event command. */
msg.data = data;
msg.data_len = 8;
data[0] = 0x21; /* Kernel generator ID, IPMI table 5-4 */
data[0] = 0x41; /* Kernel generator ID, IPMI table 5-4 */
data[1] = 0x03; /* This is for IPMI 1.0. */
data[2] = 0x20; /* OS Critical Stop, IPMI table 36-3 */
data[4] = 0x6f; /* Sensor specific, IPMI table 36-1 */