drm/amd/pm: avoid large variable on kernel stack

The activity_monitor_external[] array is too big to fit on the
kernel stack, resulting in this warning with clang:

drivers/gpu/drm/amd/amdgpu/../pm/swsmu/smu13/smu_v13_0_7_ppt.c:1438:12: error: stack frame size (1040) exceeds limit (1024) in 'smu_v13_0_7_get_power_profile_mode' [-Werror,-Wframe-larger-than]

Use dynamic allocation instead. It should also be possible to
have single element here instead of the array, but this seems
easier.

v2: fix up argument to sizeof() (Alex)

Fixes: 334682ae81 ("drm/amd/pm: enable workload type change on smu_v13_0_7")
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
Arnd Bergmann 2022-12-15 17:36:31 +01:00 коммит произвёл Alex Deucher
Родитель 1a799c4c19
Коммит d118b18fb1
1 изменённых файлов: 16 добавлений и 5 удалений

Просмотреть файл

@ -1440,7 +1440,7 @@ static int smu_v13_0_7_get_power_limit(struct smu_context *smu,
static int smu_v13_0_7_get_power_profile_mode(struct smu_context *smu, char *buf)
{
DpmActivityMonitorCoeffIntExternal_t activity_monitor_external[PP_SMC_POWER_PROFILE_COUNT];
DpmActivityMonitorCoeffIntExternal_t *activity_monitor_external;
uint32_t i, j, size = 0;
int16_t workload_type = 0;
int result = 0;
@ -1448,6 +1448,12 @@ static int smu_v13_0_7_get_power_profile_mode(struct smu_context *smu, char *buf
if (!buf)
return -EINVAL;
activity_monitor_external = kcalloc(PP_SMC_POWER_PROFILE_COUNT,
sizeof(*activity_monitor_external),
GFP_KERNEL);
if (!activity_monitor_external)
return -ENOMEM;
size += sysfs_emit_at(buf, size, " ");
for (i = 0; i <= PP_SMC_POWER_PROFILE_WINDOW3D; i++)
size += sysfs_emit_at(buf, size, "%-14s%s", amdgpu_pp_profile_name[i],
@ -1460,15 +1466,17 @@ static int smu_v13_0_7_get_power_profile_mode(struct smu_context *smu, char *buf
workload_type = smu_cmn_to_asic_specific_index(smu,
CMN2ASIC_MAPPING_WORKLOAD,
i);
if (workload_type < 0)
return -EINVAL;
if (workload_type < 0) {
result = -EINVAL;
goto out;
}
result = smu_cmn_update_table(smu,
SMU_TABLE_ACTIVITY_MONITOR_COEFF, workload_type,
(void *)(&activity_monitor_external[i]), false);
if (result) {
dev_err(smu->adev->dev, "[%s] Failed to get activity monitor!", __func__);
return result;
goto out;
}
}
@ -1496,7 +1504,10 @@ do { \
PRINT_DPM_MONITOR(Fclk_BoosterFreq);
#undef PRINT_DPM_MONITOR
return size;
result = size;
out:
kfree(activity_monitor_external);
return result;
}
static int smu_v13_0_7_set_power_profile_mode(struct smu_context *smu, long *input, uint32_t size)