SuperH IrDA: correct Baud rate error correction

It looks to me as if the second value of rate_err_array is intended
to be a decimal 625. However, with a leading 0 it becomes an octal
constant, and as such evaluates to a decimal 405.

Signed-off-by: Nicolas Kaiser <nikai@nikai.net>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Nicolas Kaiser 2010-11-18 14:24:02 +00:00 коммит произвёл David S. Miller
Родитель 33ac0b84ee
Коммит ddab1a3b30
1 изменённых файлов: 1 добавлений и 1 удалений

Просмотреть файл

@ -258,7 +258,7 @@ static int sh_sir_set_baudrate(struct sh_sir_self *self, u32 baudrate)
/* Baud Rate Error Correction x 10000 */
u32 rate_err_array[] = {
0000, 0625, 1250, 1875,
0, 625, 1250, 1875,
2500, 3125, 3750, 4375,
5000, 5625, 6250, 6875,
7500, 8125, 8750, 9375,