ahci: use 0x80 as wait stat value instead of 0xff
Before hardreset, ahci initialized stat part of received FIS area to 0xff to wait for the first D2H Reg FIS which would change the value to device ready state. This used to work but now libata considers status value of 0xff as device not present making this wait prone to failure. This patch makes ahci use 0x80 for the wait stat value instead of 0xff to fix the above problem. Signed-off-by: Tejun Heo <htejun@gmail.com> drivers/ata/ahci.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) Signed-off-by: Jeff Garzik <jeff@garzik.org>
This commit is contained in:
Родитель
d025987217
Коммит
dfd7a3db38
|
@ -903,7 +903,7 @@ static int ahci_hardreset(struct ata_port *ap, unsigned int *class)
|
|||
|
||||
/* clear D2H reception area to properly wait for D2H FIS */
|
||||
ata_tf_init(ap->device, &tf);
|
||||
tf.command = 0xff;
|
||||
tf.command = 0x80;
|
||||
ata_tf_to_fis(&tf, d2h_fis, 0);
|
||||
|
||||
rc = sata_std_hardreset(ap, class);
|
||||
|
|
Загрузка…
Ссылка в новой задаче