rt2x00: rt61pci needs another millisecond after firmware upload

After the hardware has indicated the firmware upload has completed
and the device is ready, we should wait another millisecond to
make sure the device is really ready to continue.

Without this timout, bringing the interface down and up again will
fail due to incorrect register initialization.

Signed-off-by: Ivo van Doorn <IvDoorn@gmail.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Ivo van Doorn 2008-07-27 15:06:50 +02:00 коммит произвёл John W. Linville
Родитель ada662f3eb
Коммит e6d3e90208
1 изменённых файлов: 5 добавлений и 0 удалений

Просмотреть файл

@ -1003,6 +1003,11 @@ static int rt61pci_load_firmware(struct rt2x00_dev *rt2x00dev, const void *data,
return -EBUSY;
}
/*
* Hardware needs another millisecond before it is ready.
*/
msleep(1);
/*
* Reset MAC and BBP registers.
*/