clocksource: samsung_pwm_timer: Use proper clockevents max_delta
This patch replaces hardcoded -1 argument passed to clockevents_config_and_register() with tcnt_max calculated based on variant data. This fixes invalid max delta configuration for 16-bit timers of s3c24xx. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>
This commit is contained in:
Родитель
f9bb48a2c2
Коммит
e9b852b8a7
|
@ -263,7 +263,8 @@ static void __init samsung_clockevent_init(void)
|
|||
pwm.clock_count_per_tick = clock_rate / HZ;
|
||||
|
||||
time_event_device.cpumask = cpumask_of(0);
|
||||
clockevents_config_and_register(&time_event_device, clock_rate, 1, -1);
|
||||
clockevents_config_and_register(&time_event_device,
|
||||
clock_rate, 1, pwm.tcnt_max);
|
||||
|
||||
irq_number = pwm.irq[pwm.event_id];
|
||||
setup_irq(irq_number, &samsung_clock_event_irq);
|
||||
|
|
Загрузка…