spi: atmel: use endian agnostic IO

Use the endian agnositc IO functions instead of the __raw ones for when
the driver is in use on big-endian systems.

Signed-off-by: Ben Dooks <ben.dooks@codethink.co.uk>
Acked-by: Nicolas Ferre <nicolas.ferre@atmel.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Ben Dooks 2015-03-18 15:53:08 +00:00 коммит произвёл Mark Brown
Родитель c517d838eb
Коммит ea467326e3
1 изменённых файлов: 7 добавлений и 1 удалений

Просмотреть файл

@ -180,11 +180,17 @@
| SPI_BF(name, value))
/* Register access macros */
#ifdef CONFIG_AVR32
#define spi_readl(port, reg) \
__raw_readl((port)->regs + SPI_##reg)
#define spi_writel(port, reg, value) \
__raw_writel((value), (port)->regs + SPI_##reg)
#else
#define spi_readl(port, reg) \
readl_relaxed((port)->regs + SPI_##reg)
#define spi_writel(port, reg, value) \
writel_relaxed((value), (port)->regs + SPI_##reg)
#endif
/* use PIO for small transfers, avoiding DMA setup/teardown overhead and
* cache operations; better heuristics consider wordsize and bitrate.
*/