[ALSA] mpu401: reduce tx loop timeout
Reduce the number of times to check for a non-empty Tx FIFO from 100 to 2 because there is no MPU-401 implementation that needs more than one or two reads to determine the actual FIFO status. Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
This commit is contained in:
Родитель
47ba97f8fa
Коммит
ea6b5828cd
|
@ -425,16 +425,17 @@ static void snd_mpu401_uart_input_read(struct snd_mpu401 * mpu)
|
||||||
static void snd_mpu401_uart_output_write(struct snd_mpu401 * mpu)
|
static void snd_mpu401_uart_output_write(struct snd_mpu401 * mpu)
|
||||||
{
|
{
|
||||||
unsigned char byte;
|
unsigned char byte;
|
||||||
int max = 256, timeout;
|
int max = 256;
|
||||||
|
|
||||||
do {
|
do {
|
||||||
if (snd_rawmidi_transmit_peek(mpu->substream_output,
|
if (snd_rawmidi_transmit_peek(mpu->substream_output,
|
||||||
&byte, 1) == 1) {
|
&byte, 1) == 1) {
|
||||||
for (timeout = 100; timeout > 0; timeout--) {
|
/*
|
||||||
if (snd_mpu401_output_ready(mpu))
|
* Try twice because there is hardware that insists on
|
||||||
break;
|
* setting the output busy bit after each write.
|
||||||
}
|
*/
|
||||||
if (timeout == 0)
|
if (!snd_mpu401_output_ready(mpu) &&
|
||||||
|
!snd_mpu401_output_ready(mpu))
|
||||||
break; /* Tx FIFO full - try again later */
|
break; /* Tx FIFO full - try again later */
|
||||||
mpu->write(mpu, byte, MPU401D(mpu));
|
mpu->write(mpu, byte, MPU401D(mpu));
|
||||||
snd_rawmidi_transmit_ack(mpu->substream_output, 1);
|
snd_rawmidi_transmit_ack(mpu->substream_output, 1);
|
||||||
|
|