hwmon: (f71882fg) Fix negative temperature

[ Upstream commit 4aaaaf0f27 ]

All temperature of Fintek superio hwmonitor that using 1-byte reg will use
2's complement.

In show_temp()
	temp = data->temp[nr] * 1000;

When data->temp[nr] read as 255, it indicate -1C, but this code will report
255C to userspace. It'll be ok when change to:
	temp = ((s8)data->temp[nr]) * 1000;

Signed-off-by: Ji-Ze Hong (Peter Hong) <hpeter+linux_kernel@gmail.com>
Link: https://lore.kernel.org/r/20220418090706.6339-1-hpeter+linux_kernel@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
Ji-Ze Hong (Peter Hong) 2022-04-18 17:07:06 +08:00 коммит произвёл Greg Kroah-Hartman
Родитель 41d5ad9596
Коммит f21579e443
1 изменённых файлов: 3 добавлений и 2 удалений

Просмотреть файл

@ -1577,8 +1577,9 @@ static ssize_t show_temp(struct device *dev, struct device_attribute *devattr,
temp *= 125;
if (sign)
temp -= 128000;
} else
temp = data->temp[nr] * 1000;
} else {
temp = ((s8)data->temp[nr]) * 1000;
}
return sprintf(buf, "%d\n", temp);
}