Thermal: Introduce locking for cdev.thermal_instances list.
we need to go over all the thermal_instance list of a cooling device to decide which cooling state to put the cooling device to. But at this time, as a cooling device may be referenced in multiple thermal zones, we need to lock the list first in case another thermal zone is updating this cooling device. Signed-off-by: Zhang Rui <rui.zhang@intel.com> Reviewed-by: Rafael J. Wysocki <rjw@sisk.pl> Reviewed-by: Eduardo Valentin <eduardo.valentin@ti.com>
This commit is contained in:
Родитель
908b9fb792
Коммит
f4a821ce6e
|
@ -799,6 +799,7 @@ int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
|
|||
goto remove_symbol_link;
|
||||
|
||||
mutex_lock(&tz->lock);
|
||||
mutex_lock(&cdev->lock);
|
||||
list_for_each_entry(pos, &tz->thermal_instances, tz_node)
|
||||
if (pos->tz == tz && pos->trip == trip && pos->cdev == cdev) {
|
||||
result = -EEXIST;
|
||||
|
@ -808,6 +809,7 @@ int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
|
|||
list_add_tail(&dev->tz_node, &tz->thermal_instances);
|
||||
list_add_tail(&dev->cdev_node, &cdev->thermal_instances);
|
||||
}
|
||||
mutex_unlock(&cdev->lock);
|
||||
mutex_unlock(&tz->lock);
|
||||
|
||||
if (!result)
|
||||
|
@ -840,14 +842,17 @@ int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
|
|||
struct thermal_instance *pos, *next;
|
||||
|
||||
mutex_lock(&tz->lock);
|
||||
mutex_lock(&cdev->lock);
|
||||
list_for_each_entry_safe(pos, next, &tz->thermal_instances, tz_node) {
|
||||
if (pos->tz == tz && pos->trip == trip && pos->cdev == cdev) {
|
||||
list_del(&pos->tz_node);
|
||||
list_del(&pos->cdev_node);
|
||||
mutex_unlock(&cdev->lock);
|
||||
mutex_unlock(&tz->lock);
|
||||
goto unbind;
|
||||
}
|
||||
}
|
||||
mutex_unlock(&cdev->lock);
|
||||
mutex_unlock(&tz->lock);
|
||||
|
||||
return -ENODEV;
|
||||
|
@ -913,6 +918,7 @@ thermal_cooling_device_register(char *type, void *devdata,
|
|||
}
|
||||
|
||||
strcpy(cdev->type, type);
|
||||
mutex_init(&cdev->lock);
|
||||
INIT_LIST_HEAD(&cdev->thermal_instances);
|
||||
cdev->ops = ops;
|
||||
cdev->updated = true;
|
||||
|
@ -1016,6 +1022,7 @@ static void thermal_cdev_do_update(struct thermal_cooling_device *cdev)
|
|||
if (cdev->updated)
|
||||
return;
|
||||
|
||||
mutex_lock(&cdev->lock);
|
||||
/* Make sure cdev enters the deepest cooling state */
|
||||
list_for_each_entry(instance, &cdev->thermal_instances, cdev_node) {
|
||||
if (instance->target == THERMAL_NO_TARGET)
|
||||
|
@ -1023,6 +1030,7 @@ static void thermal_cdev_do_update(struct thermal_cooling_device *cdev)
|
|||
if (instance->target > target)
|
||||
target = instance->target;
|
||||
}
|
||||
mutex_unlock(&cdev->lock);
|
||||
cdev->ops->set_cur_state(cdev, target);
|
||||
cdev->updated = true;
|
||||
}
|
||||
|
|
|
@ -95,6 +95,7 @@ struct thermal_cooling_device {
|
|||
void *devdata;
|
||||
const struct thermal_cooling_device_ops *ops;
|
||||
bool updated; /* true if the cooling device does not need update */
|
||||
struct mutex lock; /* protect thermal_instances list */
|
||||
struct list_head thermal_instances;
|
||||
struct list_head node;
|
||||
};
|
||||
|
|