iio: core: Introduce IIO_CHAN_INFO_OVERSAMPLING_RATIO

Some magnetometers can perform a number of repetitions in HW
for each measurement to increase accuracy. One example is
Bosch BMC150:
http://ae-bst.resource.bosch.com/media/products/dokumente/bmc150/BST-BMC150-DS000-04.pdf.

Introduce an interface to set the oversampling ratio
for these devices.

Signed-off-by: Irina Tirdea <irina.tirdea@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
Irina Tirdea 2015-04-29 21:16:39 +03:00 коммит произвёл Jonathan Cameron
Родитель 42a95584f3
Коммит faaa44955d
3 изменённых файлов: 14 добавлений и 0 удалений

Просмотреть файл

@ -1375,3 +1375,15 @@ Description:
The emissivity ratio of the surface in the field of view of the
contactless temperature sensor. Emissivity varies from 0 to 1,
with 1 being the emissivity of a black body.
What: /sys/bus/iio/devices/iio:deviceX/in_magn_x_oversampling_ratio
What: /sys/bus/iio/devices/iio:deviceX/in_magn_y_oversampling_ratio
What: /sys/bus/iio/devices/iio:deviceX/in_magn_z_oversampling_ratio
KernelVersion: 4.2
Contact: linux-iio@vger.kernel.org
Description:
Hardware applied number of measurements for acquiring one
data point. The HW will do <type>[_name]_oversampling_ratio
measurements and return the average value as output data. Each
value resulted from <type>[_name]_oversampling_ratio measurements
is considered as one sample for <type>[_name]_sampling_frequency.

Просмотреть файл

@ -129,6 +129,7 @@ static const char * const iio_chan_info_postfix[] = {
[IIO_CHAN_INFO_DEBOUNCE_COUNT] = "debounce_count",
[IIO_CHAN_INFO_DEBOUNCE_TIME] = "debounce_time",
[IIO_CHAN_INFO_CALIBEMISSIVITY] = "calibemissivity",
[IIO_CHAN_INFO_OVERSAMPLING_RATIO] = "oversampling_ratio",
};
/**

Просмотреть файл

@ -44,6 +44,7 @@ enum iio_chan_info_enum {
IIO_CHAN_INFO_DEBOUNCE_COUNT,
IIO_CHAN_INFO_DEBOUNCE_TIME,
IIO_CHAN_INFO_CALIBEMISSIVITY,
IIO_CHAN_INFO_OVERSAMPLING_RATIO,
};
enum iio_shared_by {