[POWERPC] spufs: synchronize IRQ when disabling
There is a small race between the context save procedure and the SPU interrupt handling, where we expect all interrupt processing to have finished after disabling them, while an interrupt is still being processed on another CPU. The obvious fix is to call synchronize_irq() after disabling the interrupts at the start of the context save procedure to make sure we never access the SPU any more during an ongoing save or even after that. Thanks to Benjamin Herrenschmidt for pointing this out. Acked-by: Benjamin Herrenschmidt <benh@kernel.crashing.org> Signed-off-by: Arnd Bergmann <arnd@arndb.de> Signed-off-by: Jeremy Kerr <jk@ozlabs.org>
This commit is contained in:
Родитель
71791bee90
Коммит
fae9ca7915
|
@ -34,6 +34,7 @@
|
|||
|
||||
#include <linux/module.h>
|
||||
#include <linux/errno.h>
|
||||
#include <linux/hardirq.h>
|
||||
#include <linux/sched.h>
|
||||
#include <linux/kernel.h>
|
||||
#include <linux/mm.h>
|
||||
|
@ -117,6 +118,8 @@ static inline void disable_interrupts(struct spu_state *csa, struct spu *spu)
|
|||
* Write INT_MASK_class1 with value of 0.
|
||||
* Save INT_Mask_class2 in CSA.
|
||||
* Write INT_MASK_class2 with value of 0.
|
||||
* Synchronize all three interrupts to be sure
|
||||
* we no longer execute a handler on another CPU.
|
||||
*/
|
||||
spin_lock_irq(&spu->register_lock);
|
||||
if (csa) {
|
||||
|
@ -129,6 +132,9 @@ static inline void disable_interrupts(struct spu_state *csa, struct spu *spu)
|
|||
spu_int_mask_set(spu, 2, 0ul);
|
||||
eieio();
|
||||
spin_unlock_irq(&spu->register_lock);
|
||||
synchronize_irq(spu->irqs[0]);
|
||||
synchronize_irq(spu->irqs[1]);
|
||||
synchronize_irq(spu->irqs[2]);
|
||||
}
|
||||
|
||||
static inline void set_watchdog_timer(struct spu_state *csa, struct spu *spu)
|
||||
|
|