hwmon: (sparx5) Fix initial reading of temperature

If the temperature is read before the internal calibration is
completed, the driver returns -EIO. Instead it should return -EAGAIN
to encourage repeating the operation.

Note (groeck): Returning -EAGAIN to userspace may result in hard loops;
some userspace code interprets -EAGAIN as request to retry immediately.
I would prefer -ENODATA, but it turns out that the thermal subsystem only
handles -EAGAIN silently, so we'll have to stick with that.

Signed-off-by: Lars Povlsen <lars.povlsen@microchip.com>
Link: https://lore.kernel.org/r/20200903134704.8949-1-lars.povlsen@microchip.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Lars Povlsen 2020-09-03 15:47:04 +02:00 коммит произвёл Guenter Roeck
Родитель ba4f184e12
Коммит fcb575bfac
1 изменённых файлов: 1 добавлений и 1 удалений

Просмотреть файл

@ -56,7 +56,7 @@ static int s5_read(struct device *dev, enum hwmon_sensor_types type,
case hwmon_temp_input: case hwmon_temp_input:
stat = readl_relaxed(hwmon->base + TEMP_STAT); stat = readl_relaxed(hwmon->base + TEMP_STAT);
if (!(stat & TEMP_STAT_VALID)) if (!(stat & TEMP_STAT_VALID))
return -EIO; return -EAGAIN;
value = stat & TEMP_STAT_TEMP; value = stat & TEMP_STAT_TEMP;
/* /*
* From register documentation: * From register documentation: