[PATCH] powerpc: Use PE configuration address consistently
236-eeh-config-addr.patch The PE configuration address wasn't being cnsistently used in all locations where a config address is called for. This patch adds it to the places it should have appeared in. Signed-off-by: Linas Vepstas <linas@austin.ibm.com> Signed-off-by: Paul Mackerras <paulus@samba.org> (cherry picked from c2bc904a28095aca0b04a37854b63b78622a032e commit)
This commit is contained in:
Родитель
821b537fd7
Коммит
fcb7543e3d
|
@ -110,6 +110,7 @@ static DEFINE_PER_CPU(unsigned long, slot_resets);
|
|||
|
||||
void eeh_slot_error_detail (struct pci_dn *pdn, int severity)
|
||||
{
|
||||
int config_addr;
|
||||
unsigned long flags;
|
||||
int rc;
|
||||
|
||||
|
@ -117,8 +118,13 @@ void eeh_slot_error_detail (struct pci_dn *pdn, int severity)
|
|||
spin_lock_irqsave(&slot_errbuf_lock, flags);
|
||||
memset(slot_errbuf, 0, eeh_error_buf_size);
|
||||
|
||||
/* Use PE configuration address, if present */
|
||||
config_addr = pdn->eeh_config_addr;
|
||||
if (pdn->eeh_pe_config_addr)
|
||||
config_addr = pdn->eeh_pe_config_addr;
|
||||
|
||||
rc = rtas_call(ibm_slot_error_detail,
|
||||
8, 1, NULL, pdn->eeh_config_addr,
|
||||
8, 1, NULL, config_addr,
|
||||
BUID_HI(pdn->phb->buid),
|
||||
BUID_LO(pdn->phb->buid), NULL, 0,
|
||||
virt_to_phys(slot_errbuf),
|
||||
|
@ -138,6 +144,7 @@ void eeh_slot_error_detail (struct pci_dn *pdn, int severity)
|
|||
static int read_slot_reset_state(struct pci_dn *pdn, int rets[])
|
||||
{
|
||||
int token, outputs;
|
||||
int config_addr;
|
||||
|
||||
if (ibm_read_slot_reset_state2 != RTAS_UNKNOWN_SERVICE) {
|
||||
token = ibm_read_slot_reset_state2;
|
||||
|
@ -148,7 +155,12 @@ static int read_slot_reset_state(struct pci_dn *pdn, int rets[])
|
|||
outputs = 3;
|
||||
}
|
||||
|
||||
return rtas_call(token, 3, outputs, rets, pdn->eeh_config_addr,
|
||||
/* Use PE configuration address, if present */
|
||||
config_addr = pdn->eeh_config_addr;
|
||||
if (pdn->eeh_pe_config_addr)
|
||||
config_addr = pdn->eeh_pe_config_addr;
|
||||
|
||||
return rtas_call(token, 3, outputs, rets, config_addr,
|
||||
BUID_HI(pdn->phb->buid), BUID_LO(pdn->phb->buid));
|
||||
}
|
||||
|
||||
|
@ -284,7 +296,7 @@ int eeh_dn_check_failure(struct device_node *dn, struct pci_dev *dev)
|
|||
return 0;
|
||||
}
|
||||
|
||||
if (!pdn->eeh_config_addr) {
|
||||
if (!pdn->eeh_config_addr && !pdn->eeh_pe_config_addr) {
|
||||
__get_cpu_var(no_cfg_addr)++;
|
||||
return 0;
|
||||
}
|
||||
|
@ -613,13 +625,20 @@ void eeh_save_bars(struct pci_dev * pdev, struct pci_dn *pdn)
|
|||
void
|
||||
rtas_configure_bridge(struct pci_dn *pdn)
|
||||
{
|
||||
int config_addr;
|
||||
int token = rtas_token ("ibm,configure-bridge");
|
||||
int rc;
|
||||
|
||||
if (token == RTAS_UNKNOWN_SERVICE)
|
||||
return;
|
||||
|
||||
/* Use PE configuration address, if present */
|
||||
config_addr = pdn->eeh_config_addr;
|
||||
if (pdn->eeh_pe_config_addr)
|
||||
config_addr = pdn->eeh_pe_config_addr;
|
||||
|
||||
rc = rtas_call(token,3,1, NULL,
|
||||
pdn->eeh_config_addr,
|
||||
config_addr,
|
||||
BUID_HI(pdn->phb->buid),
|
||||
BUID_LO(pdn->phb->buid));
|
||||
if (rc) {
|
||||
|
|
Загрузка…
Ссылка в новой задаче