mmc: sdhci: fix error conditions for controller reset
Add the case of SET_BLOCK_COUNT command error to the error conditions check for making a controller reset at request handling finish. Otherwise, if the SET_BLOCK_COUNT command failed, e.g. with a timeout, the controller state was not reset, and the next command failed too. In the case of data error the controller reset is already done in finish_data() function before sending stop command (if present), so the finish tasklet should make a reset after data error only if no stop command existed in the request. Also, fix the indentation of this condition check to make it more logical. Signed-off-by: Andrew Gabbasov <andrew_gabbasov@mentor.com> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
This commit is contained in:
Родитель
fbfaf0326b
Коммит
fce9d33f51
|
@ -2144,9 +2144,10 @@ static void sdhci_tasklet_finish(unsigned long param)
|
|||
*/
|
||||
if (!(host->flags & SDHCI_DEVICE_DEAD) &&
|
||||
((mrq->cmd && mrq->cmd->error) ||
|
||||
(mrq->data && (mrq->data->error ||
|
||||
(mrq->data->stop && mrq->data->stop->error))) ||
|
||||
(host->quirks & SDHCI_QUIRK_RESET_AFTER_REQUEST))) {
|
||||
(mrq->sbc && mrq->sbc->error) ||
|
||||
(mrq->data && ((mrq->data->error && !mrq->data->stop) ||
|
||||
(mrq->data->stop && mrq->data->stop->error))) ||
|
||||
(host->quirks & SDHCI_QUIRK_RESET_AFTER_REQUEST))) {
|
||||
|
||||
/* Some controllers need this kick or reset won't work here */
|
||||
if (host->quirks & SDHCI_QUIRK_CLOCK_BEFORE_RESET)
|
||||
|
|
Загрузка…