ASoC: Volume controls are never of boolean type

Some limited volume controls (mostly simple attenuations) have only two
settings so the ASoC info functions misreport them as booleans. Since
we currently have no better information check for " Volume" in the
control name and always report any controls matching as being integer.

Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Mark Brown 2009-04-15 21:37:46 +01:00
Родитель 3f1a4d8267
Коммит fd5dfad9cf
1 изменённых файлов: 3 добавлений и 3 удалений

Просмотреть файл

@ -1779,7 +1779,7 @@ int snd_soc_info_volsw_ext(struct snd_kcontrol *kcontrol,
{
int max = kcontrol->private_value;
if (max == 1)
if (max == 1 && !strstr(kcontrol->id.name, " Volume"))
uinfo->type = SNDRV_CTL_ELEM_TYPE_BOOLEAN;
else
uinfo->type = SNDRV_CTL_ELEM_TYPE_INTEGER;
@ -1809,7 +1809,7 @@ int snd_soc_info_volsw(struct snd_kcontrol *kcontrol,
unsigned int shift = mc->shift;
unsigned int rshift = mc->rshift;
if (max == 1)
if (max == 1 && !strstr(kcontrol->id.name, " Volume"))
uinfo->type = SNDRV_CTL_ELEM_TYPE_BOOLEAN;
else
uinfo->type = SNDRV_CTL_ELEM_TYPE_INTEGER;
@ -1916,7 +1916,7 @@ int snd_soc_info_volsw_2r(struct snd_kcontrol *kcontrol,
(struct soc_mixer_control *)kcontrol->private_value;
int max = mc->max;
if (max == 1)
if (max == 1 && !strstr(kcontrol->id.name, " Volume"))
uinfo->type = SNDRV_CTL_ELEM_TYPE_BOOLEAN;
else
uinfo->type = SNDRV_CTL_ELEM_TYPE_INTEGER;