ibmpex: report temperatures in mC, not C

ibmpex's temperature sensors report incorrect units.  Apply a conversion
factor so that tempertures report correctly.  Until now, no systems seemed to
report temperatures this way, but evidently QS2x blades do.

Signed-off-by: Darrick J. Wong <djwong@us.ibm.com>
Cc: "Mark M. Hoffman" <mhoffman@lightlink.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This commit is contained in:
Darrick J. Wong 2008-03-19 17:00:48 -07:00 коммит произвёл Linus Torvalds
Родитель 3d960a99ab
Коммит ffda6857c8
1 изменённых файлов: 1 добавлений и 1 удалений

Просмотреть файл

@ -410,7 +410,7 @@ static int ibmpex_find_sensors(struct ibmpex_bmc_data *data)
sensor_type = TEMP_SENSOR;
num_temp++;
sensor_counter = num_temp;
data->sensors[i].multiplier = 1;
data->sensors[i].multiplier = 1000;
} else
continue;