Граф коммитов

6 Коммитов

Автор SHA1 Сообщение Дата
Thomas Gleixner cd5e85f52d treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 89
Based on 1 normalized pattern(s):

  this program is free software you can redistribute it and or modify
  it under the terms of the gnu general public license version 2 or
  later as published by the free software foundation this program is
  distributed in the hope that it will be useful but without any
  warranty without even the implied warranty of merchantability or
  fitness for a particular purpose see the gnu general public license
  for more details

extracted by the scancode license scanner the SPDX license identifier

  GPL-2.0-or-later

has been chosen to replace the boilerplate/reference in 6 file(s).

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Richard Fontana <rfontana@redhat.com>
Reviewed-by: Allison Randal <allison@lohutok.net>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190520075211.856638608@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-05-24 17:37:52 +02:00
Brian Norris 986ffe0384 tools/thermal: tmon: silence 'set but not used' warnings
gcc complains about the 'cols' variable being unused. This is
unavoidable, given the ncurses getmaxyx() macro-based API, which wants
to assign to a variable directly, even when we're not going to use it.

Warning:

    gcc -O1 -Wall -Wshadow -W -Wformat -Wimplicit-function-declaration -Wimplicit-int -fstack-protector -D VERSION=\"1.0\"   -c -o tui.o tui.c
    tui.c: In function ‘show_dialogue’:
    tui.c:288:12: warning: variable ‘cols’ set but not used [-Wunused-but-set-variable]
      int rows, cols;
                ^

So, add a hack to get rid of that warning.

Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Acked-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2015-02-28 13:52:48 +08:00
Brian Norris 3bbcc529ee tools/thermal: tmon: fixup tui windowing calculations
The number of rows in the dialog vary according to the number of cooling
devices. However, some of the windowing computations were assuming a
fixed number of rows. This computation is OK when we have between 4 and
9 cooling devices (and they wrap to the next column), but with fewer
devices, we end up printing off the end of the window.

This unifies the row computation into a single function and uses that
throughout the TUI code. This also accounts for increasing the number of
rows when there are more than 9 total cooling devices.

Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Acked-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2015-02-28 13:52:47 +08:00
Brian Norris 0e7b766dc0 tools/thermal: tmon: tui: don't hard-code dialog window size assumptions
We can use the ncurses API to get the number of rows.

Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Acked-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2015-02-28 13:52:47 +08:00
Brian Norris a90b6b006c tools/thermal: tmon: add min/max macros
Signed-off-by: Brian Norris <computersforpeace@gmail.com>
Acked-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2015-02-28 13:52:47 +08:00
Jacob Pan 94f69966fa tools/thermal: Introduce tmon, a tool for thermal subsystem
Increasingly, Linux is running on thermally constrained devices. The simple
thermal relationship between processor and fan has become past for modern
computers.

As hardware vendors cope with the thermal constraints on their products,
more sensors are added, new cooling capabilities are introduced. The
complexity of the thermal relationship can grow exponentially among cooling
devices, zones, sensors, and trip points. They can also change dynamically.

To expose such relationship to the userspace, Linux generic thermal layer
introduced sysfs entry at /sys/class/thermal with a matrix of symbolic
links, trip point bindings, and device instances. To traverse such
matrix by hand is not a trivial task. Testing is also difficult in that
thermal conditions are often exception cases that hard to reach in
normal operations.

TMON is conceived as a tool to help visualize, tune, and test the
complex thermal subsystem.

Signed-off-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-11-07 08:45:34 +08:00