Граф коммитов

106 Коммитов

Автор SHA1 Сообщение Дата
Daniel Wagner 4cde03d82e nvme: consider also host_iface when checking ip options
It's perfectly fine to use the same traddr and trsvcid more than once
as long we use different host interface. This is used in setups where
the host has more than one interface but the target exposes only one
traddr/trsvcid combination.

Use the same acceptance rules for host_iface as we have for
host_traddr.

Signed-off-by: Daniel Wagner <dwagner@suse.de>
Reviewed-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-09-19 17:55:24 +02:00
Wolfram Sang a8817cc09d nvme: move from strlcpy with unused retval to strscpy
Follow the advice of the below link and prefer 'strscpy' in this
subsystem. Conversion is 1:1 because the return value is not used.
Generated by a coccinelle script.

Link: https://lore.kernel.org/r/CAHk-=wgfRnXz0W3D37d01q3JFkr_i_uTL=V6A6G1oUZcprmknw@mail.gmail.com/
Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-09-19 11:33:53 +02:00
Christophe JAILLET c50cd03dbe nvme-fabrics: Fix a typo in an error message
A 'c' is missing.
s/fabris/fabrics/

Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-08-10 16:21:31 +02:00
Amit Engel ec9e96b523 nvme-fabrics: parse nvme connect Linux error codes
This fixes the assumption that errval is an unsigned nvme error

Signed-off-by: Amit Engel <amit.engel@dell.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-08-10 16:05:10 +02:00
Hannes Reinecke f50fff73d6 nvme: implement In-Band authentication
Implement NVMe-oF In-Band authentication according to NVMe TPAR 8006.
This patch adds two new fabric options 'dhchap_secret' to specify the
pre-shared key (in ASCII respresentation according to NVMe 2.0 section
8.13.5.8 'Secret representation') and 'dhchap_ctrl_secret' to specify
the pre-shared controller key for bi-directional authentication of both
the host and the controller.
Re-authentication can be triggered by writing the PSK into the new
controller sysfs attribute 'dhchap_secret' or 'dhchap_ctrl_secret'.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
[axboe: fold in clang build fix]
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2022-08-02 17:14:49 -06:00
Hannes Reinecke 3bf2fde6fc nvme-fabrics: decode 'authentication required' connect error
The 'connect' command might fail with NVME_SC_AUTH_REQUIRED, so we
should be decoding this error, too.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2022-08-02 17:14:47 -06:00
Chaitanya Kulkarni 6b46fa024a nvme: remove unused timeout parameter
The function __nvme_submit_sync_cmd() has following list of callers
that sets the timeout value to 0 :-

        Callers               |   Timeout value
------------------------------------------------
nvme_submit_sync_cmd()        |        0
nvme_features()               |        0
nvme_sec_submit()             |        0
nvmf_reg_read32()             |        0
nvmf_reg_read64()             |        0
nvmf_reg_write32()            |        0
nvmf_connect_admin_queue()    |        0
nvmf_connect_io_queue()       |        0

Remove the timeout function parameter from __nvme_submit_sync_cmd() and
adjust the rest of code accordingly.

Signed-off-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2022-08-02 17:14:47 -06:00
Chaitanya Kulkarni 581f19dd72 nvme-fabrics: remove unnecessary braces for case
Braces are not required for enum value NVME_SC_CONNECT_INVALID_PARAM
when used on the switch-case statement, remove the braces.

Signed-off-by: Chaitanya Kulkarni <kch@nvidia.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-02-28 13:45:04 +02:00
Chaitanya Kulkarni 72b3eab456 nvme-fabrics: use consistent zeroout pattern
Remove zeroout memeset call & zeroout local variable cmd at the time
of declaration in nvmf_ref_read32() similar to what we have done in
nvmf_reg_read64(), nvmf_reg_write32(), nvmf_connect_admin_queue(), and
nvmf_connect_io_queue().

Signed-off-by: Chaitanya Kulkarni <kch@nvidia.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-02-28 13:45:04 +02:00
Chaitanya Kulkarni 0801a4b630 nvme-fabrics: use unsigned int type
Loop variable i will never have a negative value, so use
unsigned int type instaed of int.

Signed-off-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-02-28 13:45:04 +02:00
Chaitanya Kulkarni 572c97355b nvme-fabrics: use unsigned int type
Loop variable i will never have a negative value, so use
unsigned int type instaed of int.

Signed-off-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-02-28 13:45:04 +02:00
Changcheng Deng a5f3851b7f nvme-fabrics: remove the unneeded ret variable in nvmf_dev_show
Remove unneeded variable and directly return 0.

Reported-by: Zeal Robot <zealci@zte.com.cn>
Signed-off-by: Changcheng Deng <deng.changcheng@zte.com.cn>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2022-01-27 08:17:17 +01:00
Hannes Reinecke f18ee3d988 nvme-fabrics: print out valid arguments when reading from /dev/nvme-fabrics
Currently applications have a hard time figuring out which
nvme-over-fabrics arguments are supported for any given kernel;
the ioctl will return an error code on failure, and the application
has to guess whether this was due to an invalid argument or due
to a connection or controller error.
With this patch applications can read a list of supported
arguments by simply reading from /dev/nvme-fabrics, allowing
them to validate the connection string.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-12-23 11:22:45 +01:00
Maurizio Lombardi 8e8aaf512a nvme-fabrics: ignore invalid fast_io_fail_tmo values
Valid fast_io_fail_tmo values are integers >= 0 or -1 (disabled).
Prevent userspace from setting arbitrary negative values.

Signed-off-by: Maurizio Lombardi <mlombard@redhat.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-11-23 17:22:41 +01:00
Hannes Reinecke 20e8b689c9 nvme: Add connect option 'discovery'
Add a connect option 'discovery' to specify that the connection
should be made to a discovery controller, not a normal I/O controller.
With discovery controllers supporting unique subsystem NQNs we
cannot easily distinguish by the subsystem NQN if this should be
a discovery connection, but we need this information to blank out
options not supported by discovery controllers.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <kch@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-10-20 19:16:02 +02:00
Hou Pu e23439e977 nvme-fabrics: remove superfluous nvmf_host_put in nvmf_parse_options
Opts->host is NULL there. It is checked just before. So remove
nvmf_host_put. It is introduced by commit 59a2f3f00f ("nvme: fix
potential memory leak in option parsing").

Signed-off-by: Hou Pu <houpu.main@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-08-16 14:42:23 +02:00
Keith Busch be42a33b92 nvme: use blk_execute_rq() for passthrough commands
The generic blk_execute_rq() knows how to handle polled completions. Use
that instead of implementing an nvme specific handler.

Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Link: https://lore.kernel.org/r/20210610214437.641245-3-kbusch@kernel.org
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2021-06-30 15:35:38 -06:00
Chaitanya Kulkarni eff4423ec0 nvme-fabrics: remove memset in connect io q
Declare and initialize structure variable to the zero values so that we
can get rid of the zeroout memset call.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-17 15:51:19 +02:00
Chaitanya Kulkarni bfa9d1222d nvme-fabrics: remove memset in connect admin q
Declare and initialize structure variable to the zero values so that we
can get rid of the zeroout memset call.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-17 15:51:19 +02:00
Chaitanya Kulkarni c22c272013 nvme-fabrics: remove memset in nvmf_reg_write32()
Declare and initialize structure variable to the zero values so that we
can get rid of the zeroout memset call.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-17 15:51:19 +02:00
Chaitanya Kulkarni 2796a8e409 nvme-fabrics: remove memset in nvmf_reg_read64()
Declare and initialize structure variable to the zero values so that we
can get rid of the zeroout memset call.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-17 15:51:19 +02:00
Chaitanya Kulkarni 97ba6931ba nvme-fabrics: remove extra braces
No need to use the braces around ~ operator.

No functionality change in this patch.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-03 10:29:25 +03:00
Chaitanya Kulkarni 6f860c9225 nvme-fabrics: remove an extra comment
Remove the comment at the end of the switch that is not needed as
function is small enough.

No functionality change in this patch.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-03 10:29:25 +03:00
Chaitanya Kulkarni 63d20f54a3 nvme-fabrics: remove extra new lines in the switch
Remove the extra lines in the switch block that is not common practice
in the kernel code.

No functionality change in this patch.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-03 10:29:25 +03:00
Chaitanya Kulkarni 25e1de8c40 nvme-fabrics: fix the kerneldco comment for nvmf_log_connect_error()
Fix the comment style that matches existing code.

No functionality change in this patch.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-03 10:29:24 +03:00
Martin Belanger 3ede8f72a9 nvme-tcp: allow selecting the network interface for connections
In our application, we need a way to force TCP connections to go out a
specific IP interface instead of letting Linux select the interface
based on the routing tables.

Add the 'host-iface' option to allow specifying the interface to use.
When the option host-iface is specified, the driver uses the specified
interface to set the option SO_BINDTODEVICE on the TCP socket before
connecting.

This new option is needed in addtion to the existing host-traddr for
the following reasons:

Specifying an IP interface by its associated IP address is less
intuitive than specifying the actual interface name and, in some cases,
simply doesn't work. That's because the association between interfaces
and IP addresses is not predictable. IP addresses can be changed or can
change by themselves over time (e.g. DHCP). Interface names are
predictable [1] and will persist over time. Consider the following
configuration.

1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state ...
    link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
    inet 100.0.0.100/24 scope global lo
       valid_lft forever preferred_lft forever
2: enp0s3: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
    link/ether 08:00:27:21:65:ec brd ff:ff:ff:ff:ff:ff
    inet 100.0.0.100/24 scope global enp0s3
       valid_lft forever preferred_lft forever
3: enp0s8: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
    link/ether 08:00:27:4f:95:5c brd ff:ff:ff:ff:ff:ff
    inet 100.0.0.100/24 scope global enp0s8
       valid_lft forever preferred_lft forever

The above is a VM that I configured with the same IP address
(100.0.0.100) on all interfaces. Doing a reverse lookup to identify the
unique interface associated with 100.0.0.100 does not work here. And
this is why the option host_iface is required. I understand that the
above config does not represent a standard host system, but I'm using
this to prove a point: "We can never know how users will configure
their systems". By te way, The above configuration is perfectly fine
by Linux.

The current TCP implementation for host_traddr performs a
bind()-before-connect(). This is a common construct to set the source
IP address on a TCP socket before connecting. This has no effect on how
Linux selects the interface for the connection. That's because Linux
uses the Weak End System model as described in RFC1122 [2]. On the other
hand, setting the Source IP Address has benefits and should be supported
by linux-nvme. In fact, setting the Source IP Address is a mandatory
FedGov requirement (e.g. connection to a RADIUS/TACACS+ server).
Consider the following configuration.

$ ip addr list dev enp0s8
3: enp0s8: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
    link/ether 08:00:27:4f:95:5c brd ff:ff:ff:ff:ff:ff
    inet 192.168.56.101/24 brd 192.168.56.255 scope global enp0s8
       valid_lft 426sec preferred_lft 426sec
    inet 192.168.56.102/24 scope global secondary enp0s8
       valid_lft forever preferred_lft forever
    inet 192.168.56.103/24 scope global secondary enp0s8
       valid_lft forever preferred_lft forever
    inet 192.168.56.104/24 scope global secondary enp0s8
       valid_lft forever preferred_lft forever

Here we can see that several addresses are associated with interface
enp0s8. By default, Linux always selects the default IP address,
192.168.56.101, as the source address when connecting over interface
enp0s8. Some users, however, want the ability to specify a different
source address (e.g., 192.168.56.102, 192.168.56.103, ...). The option
host_traddr can be used as-is to perform this function.

In conclusion, I believe that we need 2 options for TCP connections.
One that can be used to specify an interface (host-iface). And one that
can be used to set the source address (host-traddr). Users should be
allowed to use one or the other, or both, or none. Of course, the
documentation for host_traddr will need some clarification. It should
state that when used for TCP connection, this option only sets the
source address. And the documentation for host_iface should say that
this option is only available for TCP connections.

References:
[1] https://www.freedesktop.org/wiki/Software/systemd/PredictableNetworkInterfaceNames/
[2] https://tools.ietf.org/html/rfc1122

Tested both IPv4 and IPv6 connections.

Signed-off-by: Martin Belanger <martin.belanger@dell.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-06-03 10:29:24 +03:00
Tao Chiu a97157440e nvme: move the fabrics queue ready check routines to core
queue_rq() in pci only checks if the dispatched queue (nvmeq) is ready,
e.g. not being suspended. Since nvme_alloc_admin_tags() in reset flow
restarts the admin queue, users are able to submit admin commands to a
controller before reset_work() completes. Commands submitted under this
condition may interfere with commands that performs identify, IO queue
setup in reset_work(), and may result in a hang described in the
following patch.

As seen in the fabrics, user commands are prevented from being executed
under inproper controller states. We may reuse this logic to maintain a
clear admin queue during reset_work().

Signed-off-by: Tao Chiu <taochiu@synology.com>
Signed-off-by: Cody Wong <codywong@synology.com>
Reviewed-by: Leon Chien <leonchien@synology.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-05-04 09:35:49 +02:00
Hannes Reinecke a70b81bd4d nvme: sanitize KATO setting
According to the NVMe base spec the KATO commands should be sent
at half of the KATO interval, to properly account for round-trip
times.
As we now will only ever send one KATO command per connection we
can easily use the recommended values.
This also fixes a potential issue where the request timeout for
the KATO command does not match the value in the connect command,
which might be causing spurious connection drops from the target.

Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-04-21 19:13:15 +02:00
Martin George 32feb6de47 nvme-fabrics: fix kato initialization
Currently kato is initialized to NVME_DEFAULT_KATO for both
discovery & i/o controllers. This is a problem specifically
for non-persistent discovery controllers since it always ends
up with a non-zero kato value. Fix this by initializing kato
to zero instead, and ensuring various controllers are assigned
appropriate kato values as follows:

non-persistent controllers  - kato set to zero
persistent controllers      - kato set to NVMF_DEV_DISC_TMO
                              (or any positive int via nvme-cli)
i/o controllers             - kato set to NVME_DEFAULT_KATO
                              (or any positive int via nvme-cli)

Signed-off-by: Martin George <marting@netapp.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-03-05 13:41:03 +01:00
Chao Leng ea5e5f42cd nvme-fabrics: avoid double completions in nvmf_fail_nonready_command
When reconnecting, the request may be completed with
NVME_SC_HOST_PATH_ERROR in nvmf_fail_nonready_command, which currently
set the state of the request to MQ_RQ_IN_FLIGHT before calling
nvme_complete_rq.  When this happens for a request that is freed by
the caller, such as nvme_submit_user_cmd, in the worst case the request
could be completed again in tear down process.

Instead of calling blk_mq_start_request from nvmf_fail_nonready_command,
just use the new nvme_host_path_error helper to complete the command
without starting it.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:03 +01:00
Victor Gladkov 8c4dfea97f nvme-fabrics: reject I/O to offline device
Commands get stuck while Host NVMe-oF controller is in reconnect state.
The controller enters into reconnect state when it loses connection with
the target.  It tries to reconnect every 10 seconds (default) until
a successful reconnect or until the reconnect time-out is reached.
The default reconnect time out is 10 minutes.

Applications are expecting commands to complete with success or error
within a certain timeout (30 seconds by default).  The NVMe host is
enforcing that timeout while it is connected, but during reconnect the
timeout is not enforced and commands may get stuck for a long period or
even forever.

To fix this long delay due to the default timeout, introduce new
"fast_io_fail_tmo" session parameter.  The timeout is measured in seconds
from the controller reconnect and any command beyond that timeout is
rejected.  The new parameter value may be passed during 'connect'.
The default value of -1 means no timeout (similar to current behavior).

Signed-off-by: Victor Gladkov <victor.gladkov@kioxia.com>
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2020-12-01 20:36:37 +01:00
Sagi Grimberg 73a5379937 nvme-fabrics: allow to queue requests for live queues
Right now we are failing requests based on the controller state (which
is checked inline in nvmf_check_ready) however we should definitely
accept requests if the queue is live.

When entering controller reset, we transition the controller into
NVME_CTRL_RESETTING, and then return BLK_STS_RESOURCE for non-mpath
requests (have blk_noretry_request set).

This is also the case for NVME_REQ_USER for the wrong reason. There
shouldn't be any reason for us to reject this I/O in a controller reset.
We do want to prevent passthru commands on the admin queue because we
need the controller to fully initialize first before we let user passthru
admin commands to be issued.

In a non-mpath setup, this means that the requests will simply be
requeued over and over forever not allowing the q_usage_counter to drop
its final reference, causing controller reset to hang if running
concurrently with heavy I/O.

Fixes: 35897b920c ("nvme-fabrics: fix and refine state checks in __nvmf_check_ready")
Reviewed-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2020-09-09 08:00:50 +02:00
Sagi Grimberg d7144f5c4c nvme-fabrics: don't check state NVME_CTRL_NEW for request acceptance
NVME_CTRL_NEW should never see any I/O, because in order to start
initialization it has to transition to NVME_CTRL_CONNECTING and from
there it will never return to this state.

Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2020-08-28 16:43:56 -07:00
Sagi Grimberg ecca390e80 nvme: fix deadlock in disconnect during scan_work and/or ana_work
A deadlock happens in the following scenario with multipath:
1) scan_work(nvme0) detects a new nsid while nvme0
    is an optimized path to it, path nvme1 happens to be
    inaccessible.

2) Before scan_work is complete nvme0 disconnect is initiated
    nvme_delete_ctrl_sync() sets nvme0 state to NVME_CTRL_DELETING

3) scan_work(1) attempts to submit IO,
    but nvme_path_is_optimized() observes nvme0 is not LIVE.
    Since nvme1 is a possible path IO is requeued and scan_work hangs.

--
Workqueue: nvme-wq nvme_scan_work [nvme_core]
kernel: Call Trace:
kernel:  __schedule+0x2b9/0x6c0
kernel:  schedule+0x42/0xb0
kernel:  io_schedule+0x16/0x40
kernel:  do_read_cache_page+0x438/0x830
kernel:  read_cache_page+0x12/0x20
kernel:  read_dev_sector+0x27/0xc0
kernel:  read_lba+0xc1/0x220
kernel:  efi_partition+0x1e6/0x708
kernel:  check_partition+0x154/0x244
kernel:  rescan_partitions+0xae/0x280
kernel:  __blkdev_get+0x40f/0x560
kernel:  blkdev_get+0x3d/0x140
kernel:  __device_add_disk+0x388/0x480
kernel:  device_add_disk+0x13/0x20
kernel:  nvme_mpath_set_live+0x119/0x140 [nvme_core]
kernel:  nvme_update_ns_ana_state+0x5c/0x60 [nvme_core]
kernel:  nvme_set_ns_ana_state+0x1e/0x30 [nvme_core]
kernel:  nvme_parse_ana_log+0xa1/0x180 [nvme_core]
kernel:  nvme_mpath_add_disk+0x47/0x90 [nvme_core]
kernel:  nvme_validate_ns+0x396/0x940 [nvme_core]
kernel:  nvme_scan_work+0x24f/0x380 [nvme_core]
kernel:  process_one_work+0x1db/0x380
kernel:  worker_thread+0x249/0x400
kernel:  kthread+0x104/0x140
--

4) Delete also hangs in flush_work(ctrl->scan_work)
    from nvme_remove_namespaces().

Similiarly a deadlock with ana_work may happen: if ana_work has started
and calls nvme_mpath_set_live and device_add_disk, it will
trigger I/O. When we trigger disconnect I/O will block because
our accessible (optimized) path is disconnecting, but the alternate
path is inaccessible, so I/O blocks. Then disconnect tries to flush
the ana_work and hangs.

[  605.550896] Workqueue: nvme-wq nvme_ana_work [nvme_core]
[  605.552087] Call Trace:
[  605.552683]  __schedule+0x2b9/0x6c0
[  605.553507]  schedule+0x42/0xb0
[  605.554201]  io_schedule+0x16/0x40
[  605.555012]  do_read_cache_page+0x438/0x830
[  605.556925]  read_cache_page+0x12/0x20
[  605.557757]  read_dev_sector+0x27/0xc0
[  605.558587]  amiga_partition+0x4d/0x4c5
[  605.561278]  check_partition+0x154/0x244
[  605.562138]  rescan_partitions+0xae/0x280
[  605.563076]  __blkdev_get+0x40f/0x560
[  605.563830]  blkdev_get+0x3d/0x140
[  605.564500]  __device_add_disk+0x388/0x480
[  605.565316]  device_add_disk+0x13/0x20
[  605.566070]  nvme_mpath_set_live+0x5e/0x130 [nvme_core]
[  605.567114]  nvme_update_ns_ana_state+0x2c/0x30 [nvme_core]
[  605.568197]  nvme_update_ana_state+0xca/0xe0 [nvme_core]
[  605.569360]  nvme_parse_ana_log+0xa1/0x180 [nvme_core]
[  605.571385]  nvme_read_ana_log+0x76/0x100 [nvme_core]
[  605.572376]  nvme_ana_work+0x15/0x20 [nvme_core]
[  605.573330]  process_one_work+0x1db/0x380
[  605.574144]  worker_thread+0x4d/0x400
[  605.574896]  kthread+0x104/0x140
[  605.577205]  ret_from_fork+0x35/0x40
[  605.577955] INFO: task nvme:14044 blocked for more than 120 seconds.
[  605.579239]       Tainted: G           OE     5.3.5-050305-generic #201910071830
[  605.580712] "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message.
[  605.582320] nvme            D    0 14044  14043 0x00000000
[  605.583424] Call Trace:
[  605.583935]  __schedule+0x2b9/0x6c0
[  605.584625]  schedule+0x42/0xb0
[  605.585290]  schedule_timeout+0x203/0x2f0
[  605.588493]  wait_for_completion+0xb1/0x120
[  605.590066]  __flush_work+0x123/0x1d0
[  605.591758]  __cancel_work_timer+0x10e/0x190
[  605.593542]  cancel_work_sync+0x10/0x20
[  605.594347]  nvme_mpath_stop+0x2f/0x40 [nvme_core]
[  605.595328]  nvme_stop_ctrl+0x12/0x50 [nvme_core]
[  605.596262]  nvme_do_delete_ctrl+0x3f/0x90 [nvme_core]
[  605.597333]  nvme_sysfs_delete+0x5c/0x70 [nvme_core]
[  605.598320]  dev_attr_store+0x17/0x30

Fix this by introducing a new state: NVME_CTRL_DELETE_NOIO, which will
indicate the phase of controller deletion where I/O cannot be allowed
to access the namespace. NVME_CTRL_DELETING still allows mpath I/O to
be issued to the bottom device, and only after we flush the ana_work
and scan_work (after nvme_stop_ctrl and nvme_prep_remove_namespaces)
we change the state to NVME_CTRL_DELETING_NOIO. Also we prevent ana_work
from re-firing by aborting early if we are not LIVE, so we should be safe
here.

In addition, change the transport drivers to follow the updated state
machine.

Fixes: 0d0b660f21 ("nvme: add ANA support")
Reported-by: Anton Eidelman <anton@lightbitslabs.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2020-07-29 07:45:19 +02:00
Takashi Iwai 8d8a50e20d nvme-fabrics: Use scnprintf() for avoiding potential buffer overflow
Since snprintf() returns the would-be-output size instead of the
actual output size, the succeeding calls may go beyond the given
buffer limit.  Fix it by replacing with scnprintf().

Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Signed-off-by: Keith Busch <kbusch@kernel.org>
2020-03-26 04:51:55 +09:00
Sagi Grimberg 2d352df57b nvme-fabrics: allow discovery subsystems accept a kato
This modifies the behavior of discovery subsystems to accept
a kato as a preparation to support discovery log change
events. This also means that now every discovery controller
will have a default kato value, and for non-persistent connections
the host needs to pass in a zero kato value (keep_alive_tmo=0).

Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-09-12 08:50:46 -07:00
Sagi Grimberg e7832cb48a nvme: make fabrics command run on a separate request queue
We have a fundamental issue that fabric commands use the admin_q.
The reason is, that admin-connect, register reads and writes and
admin commands cannot be guaranteed ordering while we are running
controller resets.

For example, when we reset a controller we perform:
1. disable the controller
2. teardown the admin queue
3. re-establish the admin queue
4. enable the controller

In order to perform (3), we need to unquiesce the admin queue, however
we may have some admin commands that are already pending on the
quiesced admin_q and will immediate execute when we unquiesce it before
we execute (4). The host must not send admin commands to the controller
before enabling the controller.

To fix this, we have the fabric commands (admin connect and property
get/set, but not I/O queue connect) use a separate fabrics_q and make
sure to quiesce the admin_q before we disable the controller, and
unquiesce it only after we enable the controller.

This fixes the error prints from nvmet in a controller reset storm test:
kernel: nvmet: got cmd 6 while CC.EN == 0 on qid = 0
Which indicate that the host is sending an admin command when the
controller is not enabled.

Reviewed-by:  James Smart <james.smart@broadcom.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29 12:55:03 -07:00
Israel Rukshin 52b4451a9e nvme-fabrics: Add type of service (TOS) configuration
TOS is user-defined and needs to be configured via nvme-cli.
It must be set before initiating any traffic and once set the TOS
cannot be changed.

Signed-off-by: Israel Rukshin <israelr@mellanox.com>
Reviewed-by: Max Gurtovoy <maxg@mellanox.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
2019-08-29 12:55:01 -07:00
Minwoo Im 7a1f46e3f7 nvme: introduce nvme_is_fabrics to check fabrics cmd
This patch introduces a nvme_is_fabrics() inline function to check
whether or not the given command structure is for fabrics.

Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2019-06-21 11:08:38 +02:00
Minwoo Im 94e970b674 nvme-fabrics: remove unused argument
The variable 'count' is not currently used by nvmf_create_ctrl(), so
remove it.

Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2019-05-14 17:19:43 +02:00
Minwoo Im a2faf94e57 nvme-fabrics: check more command sizes
struct common_command provides a common structure for NVMe-oF command
format.  It also needs to be checked for unintended size growth.

Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2019-05-01 09:17:27 -04:00
Christoph Hellwig 9002c4e5ff nvme-fabrics: convert to SPDX identifiers
Update license to use SPDX-License-Identifier instead of verbose license
text.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
2019-02-20 07:22:13 -07:00
Bart Van Assche a467fc55fc nvme-fabrics: document the poll function argument
This patch avoids that the kernel-doc tool reports a warning when
building with W=1.

Fixes: 26c682274e ("nvme-fabrics: allow nvmf_connect_io_queue to poll") # v5.0-rc1
Signed-off-by: Bart Van Assche <bvanassche@acm.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2019-02-20 07:18:01 -07:00
Sagi Grimberg 9846ac0143 nvme-fabrics: unset write/poll queues for discovery controllers
Even if user-space sent it to us, it got it wrong so lets
help by disallowing it.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2019-01-09 13:47:06 -05:00
Sagi Grimberg 89d43802b0 nvme-fabrics: allow user to pass in nr_poll_queues
This argument will specify how many polling I/O queues to connect when
creating the controller. These I/O queues will host I/O that is set with
REQ_HIPRI.

Reviewed-by: Steve Wise <swise@opengridcomputing.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2018-12-18 17:50:49 +01:00
Sagi Grimberg 26c682274e nvme-fabrics: allow nvmf_connect_io_queue to poll
Preparation for polling support for fabrics. Polling support
means that our completion queues are not generating any interrupts
which means we need to poll for the nvmf io queue connect as well.

Reviewed by Steve Wise <swise@opengridcomputing.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2018-12-18 17:50:48 +01:00
Sagi Grimberg 6287b51c77 nvme-core: optionally poll sync commands
Pass poll bool to indicate that we need it to poll. This prepares us for
polling support in nvmf since connect is an I/O that will be queued
and has to be polled in order to complete. If poll is passed,
we call nvme_execute_rq_polled which sends the requests and polls
for its completion.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2018-12-18 17:50:48 +01:00
Sagi Grimberg 330f6b8a70 nvme-fabrics: allow user to set nr_write_queues for separate queue maps
This argument will specify how many I/O queues will be connected in
create_ctrl in addition to nr_io_queues. With this configuration, I/O
that carries payload from the host to the target, will use the default
hctx queue map, and I/O that involves target to host transfers will use
the read hctx queue map.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2018-12-13 09:59:09 +01:00
Sagi Grimberg 20d44e8632 nvme-fabrics: allow user passing data digest
Data digest is a nvme-tcp specific feature, but nothing prevents other
transports reusing the concept so do not associate with tcp transport
solely.

Signed-off-by: Sagi Grimberg <sagi@lightbitslabs.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2018-12-13 09:58:56 +01:00
Sagi Grimberg 3b49fa8072 nvme-fabrics: allow user passing header digest
Header digest is a nvme-tcp specific feature, but nothing prevents other
transports reusing the concept so do not associate with tcp transport
solely.

Signed-off-by: Sagi Grimberg <sagi@lightbitslabs.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2018-12-13 09:58:56 +01:00