Граф коммитов

9 Коммитов

Автор SHA1 Сообщение Дата
Doron Roberts-Kedes 08ba91ee6e nbd: Add the nbd NBD_DISCONNECT_ON_CLOSE config flag.
If NBD_DISCONNECT_ON_CLOSE is set on a device, then the driver will
issue a disconnect from nbd_release if the device has no remaining
bdev->bd_openers.

Fix ret val so reconfigure with only setting the flag succeeds.

Reviewed-by: Josef Bacik <josef@toxicpanda.com>
Signed-off-by: Doron Roberts-Kedes <doronrk@fb.com>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2018-06-20 19:10:06 -06:00
Greg Kroah-Hartman e2be04c7f9 License cleanup: add SPDX license identifier to uapi header files with a license
Many user space API headers have licensing information, which is either
incomplete, badly formatted or just a shorthand for referring to the
license under which the file is supposed to be.  This makes it hard for
compliance tools to determine the correct license.

Update these files with an SPDX license identifier.  The identifier was
chosen based on the license information in the file.

GPL/LGPL licensed headers get the matching GPL/LGPL SPDX license
identifier with the added 'WITH Linux-syscall-note' exception, which is
the officially assigned exception identifier for the kernel syscall
exception:

   NOTE! This copyright does *not* cover user programs that use kernel
   services by normal system calls - this is merely considered normal use
   of the kernel, and does *not* fall under the heading of "derived work".

This exception makes it possible to include GPL headers into non GPL
code, without confusing license compliance tools.

Headers which have either explicit dual licensing or are just licensed
under a non GPL license are updated with the corresponding SPDX
identifier and the GPLv2 with syscall exception identifier.  The format
is:
        ((GPL-2.0 WITH Linux-syscall-note) OR SPDX-ID-OF-OTHER-LICENSE)

SPDX license identifiers are a legally binding shorthand, which can be
used instead of the full boiler plate text.  The update does not remove
existing license information as this has to be done on a case by case
basis and the copyright holders might have to be consulted. This will
happen in a separate step.

This patch is based on work done by Thomas Gleixner and Kate Stewart and
Philippe Ombredanne.  See the previous patch in this series for the
methodology of how this patch was researched.

Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Reviewed-by: Philippe Ombredanne <pombredanne@nexb.com>
Reviewed-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-11-02 11:20:11 +01:00
Shaun McDowell 685c9b24ad nbd: add FUA op support
NBD userland client and server have FUA (forced unit access) support
and flags defined. Make NBD kernel module recognize NBD_FLAG_SEND_FUA,
enable FUA on the queue, and forward FUA requests to the server.

Signed-off-by: Shaun McDowell <shaunjmcdowell@gmail.com>
Reviewed-by: Josef Bacik <jbacik@fb.com>
Signed-off-by: Jens Axboe <axboe@fb.com>
2017-05-30 08:20:25 -06:00
Josef Bacik a2c97909f9 nbd: add a flag to destroy an nbd device on disconnect
For ease of management it would be nice for users to specify that the
device node for a nbd device is destroyed once it is disconnected and
there are no more users.  Add a client flag and enable this operation to
happen.

Signed-off-by: Josef Bacik <jbacik@fb.com>
Signed-off-by: Jens Axboe <axboe@fb.com>
2017-04-17 09:58:42 -06:00
Jens Axboe 63db89eaf0 nbd: move multi-connection bit to unused value
Bit #7 is already used, move to bit #8 which is the first unused
one.

Fixes: 9561a7ade0 ("nbd: add multi-connection support")
Signed-off-by: Jens Axboe <axboe@fb.com>
2016-11-22 13:11:55 -07:00
Josef Bacik 9561a7ade0 nbd: add multi-connection support
NBD can become contended on its single connection.  We have to serialize all
writes and we can only process one read response at a time.  Fix this by
allowing userspace to provide multiple connections to a single nbd device.  This
coupled with block-mq drastically increases performance in multi-process cases.
Thanks,

Signed-off-by: Josef Bacik <jbacik@fb.com>
Signed-off-by: Jens Axboe <axboe@fb.com>
2016-11-22 12:16:32 -07:00
Christoph Hellwig 9dc6c806b3 nbd: stop using req->cmd
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@fb.com>
2015-05-05 13:40:44 -06:00
Alex Bligh 75f187aba5 nbd: support FLUSH requests
Currently, the NBD device does not accept flush requests from the Linux
block layer.  If the NBD server opened the target with neither O_SYNC nor
O_DSYNC, however, the device will be effectively backed by a writeback
cache.  Without issuing flushes properly, operation of the NBD device will
not be safe against power losses.

The NBD protocol has support for both a cache flush command and a FUA
command flag; the server will also pass a flag to note its support for
these features.  This patch adds support for the cache flush command and
flag.  In the kernel, we receive the flags via the NBD_SET_FLAGS ioctl,
and map NBD_FLAG_SEND_FLUSH to the argument of blk_queue_flush.  When the
flag is active the block layer will send REQ_FLUSH requests, which we
translate to NBD_CMD_FLUSH commands.

FUA support is not included in this patch because all free software
servers implement it with a full fdatasync; thus it has no advantage over
supporting flush only.  Because I [Paolo] cannot really benchmark it in a
realistic scenario, I cannot tell if it is a good idea or not.  It is also
not clear if it is valid for an NBD server to support FUA but not flush.
The Linux block layer gives a warning for this combination, the NBD
protocol documentation says nothing about it.

The patch also fixes a small problem in the handling of flags: nbd->flags
must be cleared at the end of NBD_DO_IT, but the driver was not doing
that.  The bug manifests itself as follows.  Suppose you two different
client/server pairs to start the NBD device.  Suppose also that the first
client supports NBD_SET_FLAGS, and the first server sends
NBD_FLAG_SEND_FLUSH; the second pair instead does neither of these two
things.  Before this patch, the second invocation of NBD_DO_IT will use a
stale value of nbd->flags, and the second server will issue an error every
time it receives an NBD_CMD_FLUSH command.

This bug is pre-existing, but it becomes much more important after this
patch; flush failures make the device pretty much unusable, unlike

Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
Signed-off-by: Alex Bligh <alex@alex.org.uk>
Acked-by: Paul Clements <Paul.Clements@steeleye.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2013-02-27 19:10:22 -08:00
David Howells 607ca46e97 UAPI: (Scripted) Disintegrate include/linux
Signed-off-by: David Howells <dhowells@redhat.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Thomas Gleixner <tglx@linutronix.de>
Acked-by: Michael Kerrisk <mtk.manpages@gmail.com>
Acked-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com>
Acked-by: Dave Jones <davej@redhat.com>
2012-10-13 10:46:48 +01:00