Граф коммитов

4 Коммитов

Автор SHA1 Сообщение Дата
Thomas Abraham b41511f713 mfd: Add irq domain support for max8997 interrupts
Add irq domain support for max8997 interrupts. The reverse mapping method
used is linear mapping since the sub-drivers of max8997 such as regulator
and charger drivers can use the max8997 irq_domain to get the linux irq
number for max8997 interrupts. All uses of irq_base in platform data and
max8997 driver private data are removed.

Reviwed-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Acked-by: Grant Likely <grant.likely@secretlab.ca>
Signed-off-by: Thomas Abraham <thomas.abraham@linaro.org>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2012-07-09 00:16:13 +02:00
Jesper Juhl 7785bf11f3 mfd: Remove dead code from max8997-irq
We either hit one of the case's or the default in the switch statement
in get_i2c(), so the 'return ERR_PTR(-EINVAL);' at the end of the
function is just dead code - remove it.

Signed-off-by: Jesper Juhl <jj@chaosbits.net>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2011-07-31 23:28:25 +02:00
Samuel Ortiz 8317d5178e mfd: Clean up max8997 IRQ namespace
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2011-03-27 00:09:53 +01:00
MyungJoo Ham 8de6bc7f6b mfd: Add MAX8997/8966 IRQ control
This patch enables IRQ handling for MAX8997/8966 chips.

Please note that Fuel-Gauge-related IRQs are not implemented in this
initial release. The fuel gauge module in MAX8997 is identical to
MAX17042, which is already in Linux kernel. In order to use the
already-existing MAX17042 driver for fuel gauge module in MAX8997, the
main interrupt handler of MAX8997 should relay related interrupts to
MAX17042 driver. However, in order to do this, we need to modify
MAX17042 driver as well because MAX17042 driver does not have any
interrupt handlers for now. We are not going to implement this in this
initial release as it is not crucial in basic operations of MAX8997.

Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2011-03-27 00:09:33 +01:00