More recent Wolfson hubs devices add the ability to read back the DC
servo calibration information from the register used to write offsets,
and later still ones remove the old readback registers. Add support
for the new scheme, and use it for WM8994 device revisions that
support it.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Acked-by: Liam Girdwood <lrg@slimlogic.co.uk>
Perform DC servo offset calibration using a series update sequence
rather than startup update sequence, tuning the configuration of the
WM8993 DC servo to make best use of this.
Also introduce currently unused data allowing us to correct for
any systematic errors in the DC servo calibration results and an
alternative startup path for the headphone output which performs
better with some chip revisions. The alternative setup sequence is
enabled for WM8993.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Acked-by: Liam Girdwood <lrg@slimlogic.co.uk>
The WM8993 analogue control is shared with other devices in the same
product line. Since this is a very substantial proportion of the
driver move the definitions of these controls into a new wm_hubs module
which allows them to be shared between the two.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>