Currently the read of temp using of_property_read_u32_index is reading
a u32 value into a unsigned long long. This relies on machine endianness
to work correctly, so fix this by reading a u32 value and setting temp
to this value.
Addresses-Coverity: ("Reliance on integer endianness")
Fixes: f110f3188e ("iio: temperature: Add support for LTC2983")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Acked-by: Nuno Sá <nuno.sa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The LTC2983 is a Multi-Sensor High Accuracy Digital Temperature
Measurement System. It measures a wide variety of temperature sensors and
digitally outputs the result, in °C or °F, with 0.1°C accuracy and
0.001°C resolution. It can measure the temperature of all standard
thermocouples (type B,E,J,K,N,S,R,T), standard 2-,3-,4-wire RTDs,
thermistors and diodes.
Signed-off-by: Nuno Sá <nuno.sa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>