Old users may not expect EINVAL, and there is no clear user-visibile
behavior change now that we ignore it.
Signed-off-by: Sage Weil <sage@inktank.com>
Reviewed-by: Alex Elder <elder@inktank.com>
When we are setting a new layout, fully initialize the structure:
- zero it out
- always set preferred_osd to -1
Signed-off-by: Sage Weil <sage@inktank.com>
Reviewed-by: Alex Elder <elder@inktank.com>
Both of these methods perform similar checks; move that code to a helper
so that we can ensure the checks are consistent.
Reviewed-by: Alex Elder <elder@inktank.com>
Signed-off-by: Sage Weil <sage@inktank.com>
This was an ill-conceived feature that has been removed from Ceph. Do
this gracefully:
- reject attempts to specify a preferred_osd via the ioctl
- stop exposing this information via virtual xattrs
- always fill in -1 for requests, in case we talk to an older server
- don't calculate preferred_osd placements/pgids
Reviewed-by: Alex Elder <elder@inktank.com>
Signed-off-by: Sage Weil <sage@inktank.com>
We have been using i_lock to protect all kinds of data structures in the
ceph_inode_info struct, including lists of inodes that we need to iterate
over while avoiding races with inode destruction. That requires grabbing
a reference to the inode with the list lock protected, but igrab() now
takes i_lock to check the inode flags.
Changing the list lock ordering would be a painful process.
However, using a ceph-specific i_ceph_lock in the ceph inode instead of
i_lock is a simple mechanical change and avoids the ordering constraints
imposed by igrab().
Reported-by: Amon Ott <a.ott@m-privacy.de>
Signed-off-by: Sage Weil <sage@newdream.net>
Previously we were validating the passed-in stripe unit, object size,
and stripe count against each other (and not testing most other stuff).
Instead, make sure that the composed previous layout and new values are valid,
and only send the new values to the MDS. This lets users change the
pool without setting the whole layout, for instance.
Signed-off-by: Greg Farnum <gregory.farnum@dreamhost.com>
d_parent is protected by d_lock: use it when looking up a dentry's parent
directory inode. Also take a reference and drop it in the caller to avoid
a use-after-free.
Reported-by: Al Viro <viro@ZenIV.linux.org.uk>
Reviewed-by: Yehuda Sadeh <yehuda@hq.newdream.net>
Signed-off-by: Sage Weil <sage@newdream.net>
This allows us to force IO through the sync path which you normally only
get when multiple clients are reading/writing to the same file or by
mounting with -o sync. Among other things, this lets test programs verify
correctness with a single mount.
Reviewed-by: Yehuda Sadeh <yehuda@hq.newdream.net>
Signed-off-by: Sage Weil <sage@newdream.net>
We should use ihold whenever we already have a stable inode ref, even
when we aren't holding i_lock. This avoids adding new and unnecessary
locking dependencies.
Signed-off-by: Sage Weil <sage@newdream.net>
This factors out protocol and low-level storage parts of ceph into a
separate libceph module living in net/ceph and include/linux/ceph. This
is mostly a matter of moving files around. However, a few key pieces
of the interface change as well:
- ceph_client becomes ceph_fs_client and ceph_client, where the latter
captures the mon and osd clients, and the fs_client gets the mds client
and file system specific pieces.
- Mount option parsing and debugfs setup is correspondingly broken into
two pieces.
- The mon client gets a generic handler callback for otherwise unknown
messages (mds map, in this case).
- The basic supported/required feature bits can be expanded (and are by
ceph_fs_client).
No functional change, aside from some subtle error handling cases that got
cleaned up in the refactoring process.
Signed-off-by: Sage Weil <sage@newdream.net>
Allow an application to mark a file descriptor for lazy file consistency
semantics, allowing buffered reads and writes when multiple clients are
accessing the same file.
Signed-off-by: Sage Weil <sage@newdream.net>
ceph_sb_to_client and ceph_client are really identical, we need to dump
one; while function ceph_client is confusing with "struct ceph_client",
ceph_sb_to_client's definition is more clear; so we'd better switch all
call to ceph_sb_to_client.
-static inline struct ceph_client *ceph_client(struct super_block *sb)
-{
- return sb->s_fs_info;
-}
Signed-off-by: Cheng Renquan <crquan@gmail.com>
Signed-off-by: Sage Weil <sage@newdream.net>
There is certainly no reason not to report this.
The only real downside to allowing the user to set it is that you don't
get default values by zeroing the layout struct (the default is -1).
Signed-off-by: Sage Weil <sage@newdream.net>
The endian conversions don't quite work with the old union ceph_pg. Just
make it a regular struct, and make each field __le. This is simpler and it
has the added bonus of actually working.
Signed-off-by: Sage Weil <sage@newdream.net>
A few Ceph ioctls for getting and setting file layout (striping)
parameters, and learning the identity and network address of the OSD a
given region of a file is stored on.
Signed-off-by: Sage Weil <sage@newdream.net>