Fnic Ctlr Path Trace utility is a tracing functionality built directly into fnic
driver to trace the control path frames like discovery, FLOGI request/reply,
PLOGI request/reply, link event etc. It will be one trace file for all fnics.
It will help us to debug and resolve the discovery and initialization related
issues in more convenient way. This trace information includes time stamp,
Host Number, Frame type, Frame Length and Frame. By default,64 pages are
allocated but we can change the number of allocated pages by module parameter
fnic_fc_trace_max_page. Each entry is of 256 byte and available entries are
depends on allocated number of pages. We can turn on or off the fnic control
path trace functionality by module paramter fc_trace_enable and/or reset the
trace contain by module paramter fc_trace_clear.
Signed-off-by: Hiral Shah <hishah@cisco.com>
Signed-off-by: Sesidhar Baddela <sebaddel@cisco.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This patch contains following three minor fixes.
1) During Probe, fnic was sending FIP solicitation in Non FIP mode which is not
expected, setting the internal fip state to Non FIP mode explicitly, avoids
sending FIP frame.
2) When target goes offline, all outstanding IOs belong to the target will be
terminated by driver, If the termination count is high, then it influences
firmware responsiveness. To improve the responsiveness, default IO throttle
count is reduced to 256.
3) Accessing Virtual Fabric Id (vfid) and fc_map of Fibre-Channel Forwarder(FCF)
is invalid in fnic driver when Clear Virtual Link(CVL) is received prior to
receiving flogi reject from switch. As CVL clears all FCFs.
Signed-off-by: Hiral Shah <hishah@cisco.com>
Signed-off-by: Sesidhar Baddela <sebaddel@cisco.com>
Signed-off-by: Narsimhulu Musini <nmusini@cisco.com>
Signed-off-by: Anantha Tungarakodi <atungara@cisco.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This feature gathers active and cumulative per fnic stats for io,
abort, terminate, reset, vlan discovery path and it also includes
various important stats for debugging issues. It also provided
debugfs and ioctl interface for user to retrieve these stats.
It also provides functionality to reset cumulative stats through
user interface.
Signed-off-by: Hiral Patel <hiralpat@cisco.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Preliminary to removing compare_ether_addr altogether:
Use the new bool function ether_addr_equal to add
some clarity and reduce the likelihood for misuse
of compare_ether_addr for sorting.
Done via cocci script:
$ cat compare_ether_addr.cocci
@@
expression a,b;
@@
- !compare_ether_addr(a, b)
+ ether_addr_equal(a, b)
@@
expression a,b;
@@
- compare_ether_addr(a, b)
+ !ether_addr_equal(a, b)
@@
expression a,b;
@@
- !ether_addr_equal(a, b) == 0
+ ether_addr_equal(a, b)
@@
expression a,b;
@@
- !ether_addr_equal(a, b) != 0
+ !ether_addr_equal(a, b)
@@
expression a,b;
@@
- ether_addr_equal(a, b) == 0
+ !ether_addr_equal(a, b)
@@
expression a,b;
@@
- ether_addr_equal(a, b) != 0
+ ether_addr_equal(a, b)
@@
expression a,b;
@@
- !!ether_addr_equal(a, b)
+ ether_addr_equal(a, b)
Signed-off-by: Joe Perches <joe@perches.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
If switch configured in FIP and adapter configured in non-fip mode, driver
panics while queueing FIP frame in non-existing fip_frame_queue. Added config
check before queueing FIP frame in misconfiguration case to avoid kernel panic.
Signed-off-by: Hiral Patel <hiralpat@cisco.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
FIP VLAN discovery discovers the FCoE VLAN that will be used by all other FIP
protocols as well as by the FCoE encapsulation for Fibre Channel payloads on
the established virtual link. One of the goals of FC-BB-5 was to be as
nonintrusive as possible on initiators and targets, and therefore FIP VLAN
discovery occurs in the native VLAN used by the initiator or target to
exchange Ethernet traffic. The FIP VLAN discovery protocol is the only FIP
protocol running on the native VLAN; all other FIP protocols run on the
discovered FCoE VLANs.
If an administrator has manually configured FCoE VLANs on ENodes and FCFs,
there is no need to use this protocol. FIP and FCoE will run over the
configured VLANs.
An ENode without FCoE VLANs configuration would use this automated discovery
protocol to discover over which VLANs FCoE is running.
The ENode sends a FIP VLAN discovery request to a multicast MAC address called
All-FCF-MACs, which is a multicast MAC address to which all FCFs listen.
All FCFs that can be reached in the native VLAN of the ENode are expected to
respond on the same VLAN with a response that lists one or more FCoE VLANs
that are available for the ENode's VN_Port login. This protocol has the sole
purpose of allowing the ENode to discover all the available FCoE VLANs.
Now the ENode may enable a subset of these VLANs for FCoE Running the FIP
protocol in these VLANs on a per VLAN basis. And FCoE data transactions also
would occur on this VLAN. Hence, Except for FIP VLAN discovery, all other FIP
and FCoE traffic runs on the selected FCoE VLAN. Its only the FIP VLAN
Discovery protocol that is permitted to run on the Default native VLAN of the
system.
[**** NOTE ****]
We are working on moving this feature definitions and functionality to libfcoe
module. We need this patch to be approved, as Suse is looking forward to merge
this feature in SLES 11 SP3 release. Once this patch is approved, we will
submit patch which should move vlan discovery feature to libfoce.
[Fengguang Wu <fengguang.wu@intel.com>: kmalloc cast removal]
Signed-off-by: Anantha Prakash T <atungara@cisco.com>
Signed-off-by: Hiral Patel <hiralpat@cisco.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Modified fnic driver to let hardware insert the COS value. Set bit
in descriptor to 0 telling hardware to use its lif COS configurations
to insert the COS value in the frames.
Signed-off-by: Narsimhulu Musini <nmusini@cisco.com>
Signed-off-by: Hiral Patel <hiralpat@cisco.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
fnic_flush_tx() is used to send frames held while fabric login
is in progress. The frames are held in tx_queue, but
fnic_flush_tx() was incorrectly flushing from recv_queue which
is used for received frames.
Signed-off-by: Brian Uchino <buchino@cisco.com>
Signed-off-by: Abhijeet Joglekar <abjoglek@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
percpu.h is included by sched.h and module.h and thus ends up being
included when building most .c files. percpu.h includes slab.h which
in turn includes gfp.h making everything defined by the two files
universally available and complicating inclusion dependencies.
percpu.h -> slab.h dependency is about to be removed. Prepare for
this change by updating users of gfp and slab facilities include those
headers directly instead of assuming availability. As this conversion
needs to touch large number of source files, the following script is
used as the basis of conversion.
http://userweb.kernel.org/~tj/misc/slabh-sweep.py
The script does the followings.
* Scan files for gfp and slab usages and update includes such that
only the necessary includes are there. ie. if only gfp is used,
gfp.h, if slab is used, slab.h.
* When the script inserts a new include, it looks at the include
blocks and try to put the new include such that its order conforms
to its surrounding. It's put in the include block which contains
core kernel includes, in the same order that the rest are ordered -
alphabetical, Christmas tree, rev-Xmas-tree or at the end if there
doesn't seem to be any matching order.
* If the script can't find a place to put a new include (mostly
because the file doesn't have fitting include block), it prints out
an error message indicating which .h file needs to be added to the
file.
The conversion was done in the following steps.
1. The initial automatic conversion of all .c files updated slightly
over 4000 files, deleting around 700 includes and adding ~480 gfp.h
and ~3000 slab.h inclusions. The script emitted errors for ~400
files.
2. Each error was manually checked. Some didn't need the inclusion,
some needed manual addition while adding it to implementation .h or
embedding .c file was more appropriate for others. This step added
inclusions to around 150 files.
3. The script was run again and the output was compared to the edits
from #2 to make sure no file was left behind.
4. Several build tests were done and a couple of problems were fixed.
e.g. lib/decompress_*.c used malloc/free() wrappers around slab
APIs requiring slab.h to be added manually.
5. The script was run on all .h files but without automatically
editing them as sprinkling gfp.h and slab.h inclusions around .h
files could easily lead to inclusion dependency hell. Most gfp.h
inclusion directives were ignored as stuff from gfp.h was usually
wildly available and often used in preprocessor macros. Each
slab.h inclusion directive was examined and added manually as
necessary.
6. percpu.h was updated not to include slab.h.
7. Build test were done on the following configurations and failures
were fixed. CONFIG_GCOV_KERNEL was turned off for all tests (as my
distributed build env didn't work with gcov compiles) and a few
more options had to be turned off depending on archs to make things
build (like ipr on powerpc/64 which failed due to missing writeq).
* x86 and x86_64 UP and SMP allmodconfig and a custom test config.
* powerpc and powerpc64 SMP allmodconfig
* sparc and sparc64 SMP allmodconfig
* ia64 SMP allmodconfig
* s390 SMP allmodconfig
* alpha SMP allmodconfig
* um on x86_64 SMP allmodconfig
8. percpu.h modifications were reverted so that it could be applied as
a separate patch and serve as bisection point.
Given the fact that I had only a couple of failures from tests on step
6, I'm fairly confident about the coverage of this conversion patch.
If there is a breakage, it's likely to be something in one of the arch
headers which should be easily discoverable easily on most builds of
the specific arch.
Signed-off-by: Tejun Heo <tj@kernel.org>
Guess-its-ok-by: Christoph Lameter <cl@linux-foundation.org>
Cc: Ingo Molnar <mingo@redhat.com>
Cc: Lee Schermerhorn <Lee.Schermerhorn@hp.com>
Use libfcoe as a common FIP implementation with fcoe.
FIP or non-FIP mode is fully automatic if the firmware
supports and enables it.
Even if FIP is not supported, this uses libfcoe for the non-FIP
handling of FLOGI and its response.
Use the new lport_set_port_id() notification to capture
successful FLOGI responses and port_id resets.
While transitioning between Ethernet and FC mode, all rx and
tx FC frames are queued. In Ethernet mode, all frames are
passed to the exchange manager to capture FLOGI responses.
Change to set data_src_addr to the ctl_src_addr whenever it
would have previously been zero because we're not logged in.
This seems safer so we'll never send a frame with a 0 source MAC.
This also eliminates a special case for sending FLOGI frames.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Modifies current code to use EM anchor list in EM allocation, EM free,
EM reset, exch allocation and exch lookup code paths.
1. Modifies fc_exch_mgr_alloc to accept EM match function and then
have allocated EM added to the lport using fc_exch_mgr_add API
while also updating EM kref for newly added EM.
2. Updates fc_exch_mgr_free API to accept only lport pointer instead
EM and then have this API free all EMs of the lport from EM anchor
list.
3. Removes single lport pointer link from the EM, which was used in
associating lport pointer in newly allocated exchange. Instead have
lport pointer passed along new exchange allocation call path and
then store passed lport pointer in newly allocated exchange, this
will allow a single EM instance to be used across more than one
lport and used in EM reset to reset only lport specific exchanges.
4. Modifies fc_exch_mgr_reset to reset all EMs from the EM anchor list
of the lport, adds additional exch lport pointer (ep->lp) check for
shared EM case to reset exchange specific to a lport requested reset.
5. Updates exch allocation API fc_exch_alloc to use EM anchor list and
its anchor match func pointer. The fc_exch_alloc will walk the list
of EMs until it finds a match, a match will be either null match
func pointer or call to match function returning true value.
6. Updates fc_exch_recv to accept incoming frame on local port using
only lport pointer and frame pointer without specifying EM instance
of incoming frame. Instead modified fc_exch_recv to locate EM for the
incoming frame by matching xid of incoming frame against a EM xid range.
This change was required to use EM list in libfc Rx path and after this
change the lport fc_exch_mgr pointer emp is not needed anymore, so
removed emp pointer.
7. Updates fnic for removed lport emp pointer and above modified libfc APIs
fc_exch_recv, fc_exch_mgr_alloc and fc_exch_mgr_free.
8. Removes exch_get and exch_put from libfc_function_template as these
are no longer needed with EM anchor list and its match function use.
Also removes its default function fc_exch_get.
A defect this patch introduced regarding the libfc initialization order in
the fnic driver was fixed by Joe Eykholt <jeykholt@cisco.com>.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
fnic is a driver for the Cisco PCI-Express FCoE HBA
Signed-off-by: Abhijeet Joglekar <abjoglek@cisco.com>
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>