The type of loaddr is u8 which is always '<=' 0xff, so the
loaddr <= 0xff is always true, we can remove this comparison.
Reported-by: Hulk Robot <hulkci@huawei.com>
Signed-off-by: Yang Yingliang <yangyingliang@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Fix sparse warnings:
drivers/ptp/ptp_idt82p33.c:26:5: warning: symbol 'sync_tod_timeout' was not declared. Should it be static?
drivers/ptp/ptp_idt82p33.c:31:5: warning: symbol 'phase_snap_threshold' was not declared. Should it be static?
Reported-by: Hulk Robot <hulkci@huawei.com>
Signed-off-by: YueHaibing <yuehaibing@huawei.com>
Acked-by: Richard Cochran <richardcochran@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The IDT 82P33 Synchronization Management Unit (SMU) family provides
tools to manage timing references, clock sources and
timing paths for IEEE 1588 / Precision Time Protocol (PTP) and
Synchronous Ethernet (SyncE) based clocks. The device supports up
to three independent timing paths that control: PTP clock synthesis;
SyncE clock generation; and general purpose frequency translation.
The device supports physical layer timing with Digital PLLs (DPLLs)
and it supports packet based timing with Digitally Controlled
Oscillators (DCOs). This patch adds support for ptp clock based on
the device.
Changes since v1:
- As suggested by Richard Cochran:
1. Replace _mask_bit_count with the existing hweight8
2. Prefix all functions with idt82p33
3. Fix white space issues in Kconfig and Makefile
4. Remove forward declaration
5. Use adjfine instead of adjfreq for better resolution
- As suggested by David Miller:
1. Replace CHAN_INIT macro with a static function
idt82p33_channel_init
2. Employ reverse christmas tree ordering for local
variables
3. Fix indentation problem by appropriate number of
TAB then SPACE character
Signed-off-by: Min Li <min.li.xe@renesas.com>