This patch makes the bus-error reporting configurable and allows to
retrieve the CAN TX and RX bus error counters via netlink interface.
I have added support for the SJA1000. The TX and RX bus error counters
are also copied to the data fields 6..7 of error messages when state
changes are reported.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds the flag CAN_CTRLMODE_ONE_SHOT. It is used as mask
or flag in the "struct can_ctrlmode".
It allows userspace via netlink to set a CAN controller into the special
"one-shot" mode. In this mode, if supported by the CAN controller, it
tries only once to deliver a CAN frame and aborts it if an error
(e.g.: arbitration lost) happens.
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Acked-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The CAN network device driver interface provides a generic interface to
setup, configure and monitor CAN network devices. It exports a set of
common data structures and functions, which all real CAN network device
drivers should use. Please have a look to the SJA1000 or MSCAN driver
to understand how to use them. The name of the module is can-dev.ko.
Furthermore, it adds a Netlink interface allowing to configure the CAN
device using the program "ip" from the iproute2 utility suite.
For further information please check "Documentation/networking/can.txt"
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Oliver Hartkopp <oliver.hartkopp@volkswagen.de>
Signed-off-by: David S. Miller <davem@davemloft.net>