The flag MICREL_PHY_50MHZ_CLK is not of exclusive use of KSZ8051
model. At least KSZ8021 and KSZ8031 models also use it.
This patch moves the handling of this and future flags to a
separate function so that the different PHY models can call it on
their init function, if needed.
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Micrel PHY KSZ8031 is similar to KSZ8021 and also requires the special
initialization of "Operation Mode Strap Override" in reg 0x16
introduced in 212ea99 (phy/micrel: Implement support for KSZ8021).
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
Reviewed-by: Marek Vasut <marex@denx.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Phyter KSZ9021 has hardware bug. If asymmetric pause is enabled,
then it is necessary to disconnect and then reconnect the ethernet
cable to get the phyter working. The solution is to disable the
asymmetric pause.
Signed-off-by: Vlastimil Kosar <ikosar@fit.vutbr.cz>
Signed-off-by: David S. Miller <davem@davemloft.net>
Summary of changes:
.Newly added phys
-KSZ8081/KSZ8091, which has some phy ids.
-KSZ8061
-KSZ9031, which is Gigabit phy.
-KSZ886X, which has a switch function.
-KSZ8031, which has a same phy ids with KSZ8021.
Signed-off-by: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
this will allow to detect the link between the switch and the soc
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
Cc: netdev@vger.kernel.org
Signed-off-by: David S. Miller <davem@davemloft.net>
There is no such part as KS8001, KS8041 or KS8051. There are only
KSZ8001, KSZ8041 and KSZ8051. Rename these parts as such to match
the Micrel naming.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Cc: Linux ARM kernel <linux-arm-kernel@lists.infradead.org>
Cc: Fabio Estevam <fabio.estevam@freescale.com>
Cc: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
The KSZ8021 PHY was previously caught by KS8051, which is not correct.
This PHY needs additional setup if it is strapped for address 0. In such
case an reserved bit must be written in the 0x16, "Operation Mode Strap
Override" register. According to the KS8051 datasheet, that bit means
"PHY Address 0 in non-broadcast" and it indeed behaves as such on KSZ8021.
The issue where the ethernet controller (Freescale FEC) did not communicate
with network is fixed by writing this bit as 1.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If registering of one of them fails, all already registered drivers
of this module will be unregistered.
Use the new register/unregister functions in all drivers
registering more than one driver.
amd.c, realtek.c: Simplify: directly return registration result.
Tested with broadcom.c
All others compile-tested.
Signed-off-by: Christian Hohnstaedt <chohnstaedt@innominate.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
On a freescale imx6q platform, a hardware phy chip KSZ9021 is
recognized as a KS8001 chip by the current driver like this:
eth0: Freescale FEC PHY driver [Micrel KS8001 or KS8721]
KSZ9021 has phy_id 0x00221610, while KSZ8001 has phy_id
0x0022161a, the current phy_id_mask (0x00fffff0/0x00ffff10) can't
distinguish them. So change phy_id_mask to resolve this problem.
Although the micrel datasheet says that the 4 LSB of phyid2 register
contains the chip revision number and the current driver is designed
to follow this rule, in reality the chip implementation doesn't follow
it.
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Signed-off-by: Hui Wang <jason77.wang@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Platform code can now set the MICREL_PHY_50MHZ_CLK bit of dev_flags in a fixup
routine (registered with phy_register_fixup_for_uid()), to make the KZS8051RNL
PHY work with 50MHz RMII reference clock.
Cc: David J. Choi <david.choi@micrel.com>
Signed-off-by: Baruch Siach <baruch@tkos.co.il>
Signed-off-by: David S. Miller <davem@davemloft.net>
MODULE_DEVICE_TABLE only expands to something if it's compiled
for a module. So when building-in support for the phys, the
mdio_device_id tables are unused. Marking them with __maybe_unused
fixes the following warnings:
drivers/net/phy/bcm63xx.c:134: warning: 'bcm63xx_tbl' defined but not used
drivers/net/phy/broadcom.c:933: warning: 'broadcom_tbl' defined but not used
drivers/net/phy/cicada.c:162: warning: 'cicada_tbl' defined but not used
drivers/net/phy/davicom.c:222: warning: 'davicom_tbl' defined but not used
drivers/net/phy/et1011c.c:114: warning: 'et1011c_tbl' defined but not used
drivers/net/phy/icplus.c:137: warning: 'icplus_tbl' defined but not used
drivers/net/phy/lxt.c:226: warning: 'lxt_tbl' defined but not used
drivers/net/phy/marvell.c:724: warning: 'marvell_tbl' defined but not used
drivers/net/phy/micrel.c:234: warning: 'micrel_tbl' defined but not used
drivers/net/phy/national.c:154: warning: 'ns_tbl' defined but not used
drivers/net/phy/qsemi.c:141: warning: 'qs6612_tbl' defined but not used
drivers/net/phy/realtek.c:82: warning: 'realtek_tbl' defined but not used
drivers/net/phy/smsc.c:257: warning: 'smsc_tbl' defined but not used
drivers/net/phy/ste10Xp.c:135: warning: 'ste10Xp_tbl' defined but not used
drivers/net/phy/vitesse.c:195: warning: 'vitesse_tbl' defined but not used
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Hello all:
This patch fixes what Ben mentioned, namely duplicated ids.
From: David J. Choi <david.choi@micrel.com>
Body of the explanation: This patch has changes as followings;
-support the interrupt from phy devices from Micrel Inc.
-support more phy devices, ks8737, ks8721, ks8041, ks8051 from Micrel.
-remove vsc8201 because this device was used only internal test at Micrel.
Signed-off-by: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Missing name string in ks8001_driver, so we crash on register.
Reported-by: Ingo Molnar <mingo@elte.hu>
Tested-by: Ingo Molnar <mingo@elte.hu>
Signed-off-by: David S. Miller <davem@davemloft.net>
This is the first version of phy driver from Micrel Inc.
Signed-off-by: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>