Tim Harvey c1ae18d313 hwmon: (gsc-hwmon) Scale temperature to millidegrees
The GSC registers report temperature in decidegrees celcius so we
need to scale it to represent the hwmon sysfs API of millidegrees.

Cc: stable@vger.kernel.org
Fixes: 3bce5377ef ("hwmon: Add Gateworks System Controller support")
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
Link: https://lore.kernel.org/r/1598548824-16898-1-git-send-email-tharvey@gateworks.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-08-27 12:47:55 -07:00
Tim Harvey a4872f7a4b hwmon: (gsc) add 16bit pre-scaled voltage mode
add a 16-bit pre-scaled voltage mode to adc and clarify that existing
pre-scaled mode is 24bit.

Signed-off-by: Tim Harvey <tharvey@gateworks.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Link: https://lore.kernel.org/r/1591714640-10332-3-git-send-email-tharvey@gateworks.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-07-19 16:25:21 -07:00
Tim Harvey 3bce5377ef hwmon: Add Gateworks System Controller support
The Gateworks System Controller has a hwmon sub-component that exposes
up to 16 ADC's, some of which are temperature sensors, others which are
voltage inputs. The ADC configuration (register mapping and name) is
configured via device-tree and varies board to board.

Signed-off-by: Tim Harvey <tharvey@gateworks.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
2020-05-20 10:29:17 +01:00