Add support for CCS811 VOC sensor. This patch adds support
for reading current and voltage across the sensor and TVOC
and equivalent CO2 values.
Scale and offset values have been computed according to datasheet:
- For current: raw value is in microamps
=> 0.001 scale to convert to milliamps
- For voltage: 1.65V = 1023, therefore 1650mV = 1023
=> 1650.0/1023 = 1.612903 scale to convert to millivolts
- For eCO2: raw value range is from 400ppm to 8192ppm.
=> (val - 400) * (100 - 0) / (8192 - 400) + 0 =
(val - 400) * 0.01283367 => offset: -400, scale = 0.012834
to get a percentage value
-For TVOC: raw value range is from 0ppb to 1187ppb.
=> (val - 0) * 100 / (1187 - 0) + 0 = val * 0.0842459 =>
scale = 0.084246 for getting a percentage value
Cc: Daniel Baluta <daniel.baluta@gmail.com>
Cc: Alison Schofield <amsfield22@gmail.com>
Signed-off-by: Narcisa Ana Maria Vasile <narcisaanamaria12@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add support for the Atlas Scientific pH-SM chemical sensor that can
detect pH levels of solutions in the range of 0-14.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add support for AMS iAQ-core continuous and pulsed VOC sensors.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add support for VZ89X sensors VOC and CO2 reporting channels in
percentage which can be converted to part per million.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>