Jesper Juhl f80ea66808 BMP085: Remove redundant semi-colon from return statement
Just a single ";" will do nicely.

Signed-off-by: Jesper Juhl <jj@codesealer.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
2012-01-04 15:21:56 -08:00
Lucas De Marchi 25985edced Fix common misspellings
Fixes generated by 'codespell' and manually reviewed.

Signed-off-by: Lucas De Marchi <lucas.demarchi@profusion.mobi>
2011-03-31 11:26:23 -03:00
Shubhrajyoti Datta 45bff2ea42 drivers/misc/bmp085.c: free initmem memory
Free the memory that is used only at init

Signed-off-by: Shubhrajyoti Datta <shubhrajyoti@ti.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-03-22 17:44:10 -07:00
Axel Lin 97e419a082 drivers/misc/bmp085.c: add MODULE_DEVICE_TABLE
The device table is required to load modules based on modaliases.

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Cc: Shubhrajyoti D <shubhrajyoti@ti.com>
Cc: Christoph Mair <christoph.mair@gmail.com>
Cc: Jonathan Cameron <jic23@cam.ac.uk>
Cc: <stable@kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-03-04 17:53:38 -08:00
Christoph Mair 5bf1d290b5 drivers/misc: support for the pressure sensor BMP085 from Bosch Sensortec
This driver adds support for the BMP085 digital pressure sensor from Bosch
Sensortec.  It exposes a sysfs api to userspace where pressure and
temperature measurement results can be read from the pressure0_input and
temp0_input file.  The chip is able to calculate the average of up to
eight samples to increase the accuracy.  This feature can be controlled by
writing to the oversampling file.

The BMP085 digital pressure sensor can measure ambient air pressure and
temperature.  Both values can be obtained from sysfs files.  The pressure
is measured by reading from pressure0_input.  Valid values range from
30000 to 110000 pascal with a resolution of 1 pascal (=0.01 millibar).

temp0_input holds the current temperature in degree celsius, multiplied by
10.  This results in a resolution of a tenth degree celsius.  Values range
from -400 to 850.

To increase the accuracy, this chip can calculate the average of 1, 2, 4
or 8 samples.  This behavior is controlled through the oversampling sysfs
file.  Two to the power of the value written to that file specifies how
many samples will be used.  Valid values: 0..3.

[akpm@linux-foundation.org: fix typo]
[shubhrajyoti@ti.com: optimize the wait time for the pressure sensor, definition of long is arch dependent so make it u32]
[akpm@linux-foundation.org: coding-style fixes]
Signed-off-by: Christoph Mair <christoph.mair@gmail.com>
Signed-off-by: Shubhrajyoti D <shubhrajyoti@ti.com>
Acked-by: Jonathan Cameron <jic23@cam.ac.uk>
Cc: Stefan Schmidt <stefan@datenfreihafen.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2010-08-09 20:45:05 -07:00