Граф коммитов

6 Коммитов

Автор SHA1 Сообщение Дата
Daniel Lezcano 1727339590 clocksource/drivers: Rename CLOCKSOURCE_OF_DECLARE to TIMER_OF_DECLARE
The CLOCKSOURCE_OF_DECLARE macro is used widely for the timers to declare the
clocksource at early stage. However, this macro is also used to initialize
the clockevent if any, or the clockevent only.

It was originally suggested to declare another macro to initialize a
clockevent, so in order to separate the two entities even they belong to the
same IP. This was not accepted because of the impact on the DT where splitting
a clocksource/clockevent definition does not make sense as it is a Linux
concept not a hardware description.

On the other side, the clocksource has not interrupt declared while the
clockevent has, so it is easy from the driver to know if the description is
for a clockevent or a clocksource, IOW it could be implemented at the driver
level.

So instead of dealing with a named clocksource macro, let's use a more generic
one: TIMER_OF_DECLARE.

The patch has not functional changes.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Neil Armstrong <narmstrong@baylibre.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Matthias Brugger <matthias.bgg@gmail.com>
Reviewed-by: Linus Walleij <linus.walleij@linaro.org>
2017-06-14 11:58:45 +02:00
Rafał Miłecki ac9ce6d1a0 clocksource: Add missing line break to error messages
Printing with pr_* functions requires adding line break manually.

Signed-off-by: Rafał Miłecki <rafal@milecki.pl>
Acked-by: Thierry Reding <treding@nvidia.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
2017-04-07 16:23:04 +02:00
Daniel Lezcano 177cf6e52b clocksources: Switch back to the clksrc table
All the clocksource drivers's init function are now converted to return
an error code. CLOCKSOURCE_OF_DECLARE is no longer used as well as the
clksrc-of table.

Let's convert back the names:
 - CLOCKSOURCE_OF_DECLARE_RET => CLOCKSOURCE_OF_DECLARE
 - clksrc-of-ret              => clksrc-of

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>

For exynos_mct and samsung_pwm_timer:
Acked-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>

For arch/arc:
Acked-by: Vineet Gupta <vgupta@synopsys.com>

For mediatek driver:
Acked-by: Matthias Brugger <matthias.bgg@gmail.com>

For the Rockchip-part
Acked-by: Heiko Stuebner <heiko@sntech.de>

For STi :
Acked-by: Patrice Chotard <patrice.chotard@st.com>

For the mps2-timer.c and versatile.c changes:
Acked-by: Liviu Dudau <Liviu.Dudau@arm.com>

For the OXNAS part :
Acked-by: Neil Armstrong <narmstrong@baylibre.com>

For LPC32xx driver:
Acked-by: Sylvain Lemieux <slemieux.tyco@gmail.com>

For Broadcom Kona timer change:
Acked-by: Ray Jui <ray.jui@broadcom.com>

For Sun4i and Sun5i:
Acked-by: Chen-Yu Tsai <wens@csie.org>

For Meson6:
Acked-by: Carlo Caione <carlo@caione.org>

For Keystone:
Acked-by: Santosh Shilimkar <ssantosh@kernel.org>

For NPS:
Acked-by: Noam Camus <noamca@mellanox.com>

For bcm2835:
Acked-by: Eric Anholt <eric@anholt.net>
2016-06-28 10:19:35 +02:00
Daniel Lezcano 2ef2538bc6 clocksource/drivers/sp804: Convert init function to return error
The init functions do not return any error. They behave as the following:

  - panic, thus leading to a kernel crash while another timer may work and
       make the system boot up correctly

  or

  - print an error and let the caller unaware if the state of the system

Change that by converting the init functions to return an error conforming
to the CLOCKSOURCE_OF_RET prototype.

Proper error handling (rollback, errno value) will be changed later case
by case, thus this change just return back an error or success in the init
function.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
2016-06-28 10:19:30 +02:00
Viresh Kumar daea72831d clockevents/drivers/timer-sp804: Migrate to new 'set-state' interface
Migrate timer-sp driver to the new 'set-state' interface provided by
clockevents core, the earlier 'set-mode' interface is marked obsolete
now.

This also enables us to implement callbacks for new states of clockevent
devices, for example: ONESHOT_STOPPED.

There are few more changes worth noticing:

- The clockevent device was disabled by writing: 'TIMER_CTRL_32BIT |
  TIMER_CTRL_IE' to ctrl register earlier. i.e. by un-setting the
  TIMER_CTRL_ENABLE bit. Its done by writing zero now and should have
  the same effect.

- For shutdown and resume we were writing the same value twice to the
  register (to disable the timer), which is fixed now.

- Switching to oneshot mode was divided into two parts earlier:
  - Firstly set_mode() was writing:
    'TIMER_CTRL_32BIT | TIMER_CTRL_IE | TIMER_CTRL_ONESHOT'
    to ctrl register (device not enabled yet)
  - Then sp804_set_next_event() was enabling the device by writing
    'readl(ctrl) | TIMER_CTRL_ENABLE' to the ctrl register. This was
    unnecessarily complicated.
  - Change this to: Stop device on set_state_oneshot and configure it in
    sp804_set_next_event().

Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Cc: Russell King <rmk+kernel@arm.linux.org.uk>
Cc: Sudeep Holla <sudeep.holla@arm.com>
Cc: Arnd Bergmann <arnd@arndb.de>
Cc: Catalin Marinas <catalin.marinas@arm.com>
Cc: Olof Johansson <olof@lixom.net>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
2015-08-10 11:40:55 +02:00
Sudeep Holla 0b7402dce4 ARM: 8366/1: move Dual-Timer SP804 driver to drivers/clocksource
The ARM Dual-Timer SP804 module is peripheral found not only on ARM32
platforms but also on ARM64 platforms.

This patch moves the driver out of arch/arm to driver/clocksource
so that it can be used on ARM64 platforms also.

Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Cc: Rob Herring <robh@kernel.org>
Cc: Arnd Bergmann <arnd@arndb.de>
Cc: Catalin Marinas <catalin.marinas@arm.com>
Cc: Olof Johansson <olof@lixom.net>
Acked-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Sudeep Holla <sudeep.holla@arm.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
2015-06-02 09:58:18 +01:00